Product Details

Product Overview

The Allen Bradley 22A-D2P3N104 belongs to the PowerFlex 4 family, providing a compact and cost-effective solution for speed control of three-phase induction motors. This drive delivers 1.0 HP (0.75 kW) of power, making it ideal for machine level speed control in fans, pumps, and conveyors. We supply this unit as 100% Brand New original hardware, featuring an integrated LED keypad and RS485 communication for seamless industrial integration.

Part Number Breakdown

The 22A-D2P3N104 follows a specific coding logic for the PowerFlex 4 series:

  • 22A: Identifies the PowerFlex 4 Drive Series.

  • D: Indicates the 380–480V AC Input Voltage.

  • 2P3: Represents the 2.3 Amp current rating (0.75 kW / 1.0 HP).

  • N: Signifies an IP20 / NEMA UL Type Open enclosure.

  • 1: Indicates a Fixed Keypad interface.

  • 0: Specifies the version without a CE compliant filter.

  • 4: Standard Brake Drive configuration.

Technical Specifications

The following table outlines the critical electrical and physical parameters of the drive:

Feature Specification
Input Power 380–480V AC, 3-Phase
Rated Output Power 0.75 kW (1.0 HP)
Output Current 2.3 Amps (Continuous)
Frequency Range 0–240 Hz
Enclosure Rating IP20 / NEMA UL Type Open
Communication Built-in RS485 Port
I/O Terminals 3 Fixed Inputs, 2 Programmable Inputs, 1 Relay Output
Analog Inputs 1 (0–10V or 4–20 mA)
Weight 3.00 lbs (1.36 kg)

Engineering Advantages

  • Space-Saving Design: The "Zero Stacking" feature allows side-by-side installation without clearance between drives. This reduces the total enclosure size required for multi-axis systems.

  • Integrated Dynamic Braking: The built-in brake chopper eliminates the need for external control modules when connecting dynamic braking resistors, effectively managing regenerative energy during rapid motor deceleration.

  • Versatile I/O Configuration: Five discrete inputs (including three fixed for Start/Stop/Reverse) and two fully programmable analog/digital options provide enough flexibility to handle most standalone machine logic without an external PLC.

  • Simplified Commissioning: The integral LED keypad allows for immediate parameter adjustment. Users can clone configurations across multiple drives using the standard RS485 port and DriveExplorer software, significantly shortening setup times.

FAQs

  • Does the 22A-D2P3N104 include an internal EMC filter?

    No, this specific model (ending in '104') does not include an internal CE compliant filter. If your application requires strict electromagnetic compatibility compliance, you must install an external line filter.

  • Can I mount this drive outside of a control panel?

    The IP20 / NEMA Open Type rating requires installation inside a protective cabinet. This protects the electronics from dust, moisture, and accidental contact with live terminals.

  • What is the maximum output frequency supported?

    The PowerFlex 4 supports an output frequency up to 240 Hz, which accommodates high-speed spindle applications or specialized motor requirements.

  • How does the drive handle high-torque startups?

    The drive utilizes Volts per Hertz (V/Hz) control with programmable torque boost, ensuring the motor generates sufficient torque to break static friction in conveyor and heavy-load applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more