Overview

The Allen-Bradley 20-COMM-D is a DeviceNet communication adapter developed for PowerFlex AC drives and SMC controllers. It provides seamless integration between drives and DeviceNet networks, supporting high-speed communication rates and real-time control data exchange for advanced automation systems.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PowerFlex Series

  • Part Number: 20-COMM-D

  • Product Type: DeviceNet Communication Adapter

  • Compatible Drives: PowerFlex 70, 700, 700H, 700S, 700L, 750 series; also compatible with PowerFlex Digital AC drives, SMC Flex, and SMC-50 smart motor controllers

  • Communication Protocols: DeviceNet, DPI (Drive Peripheral Interface)

  • Communication Ports:

    • 1 DPI connector

    • 1 DeviceNet connector

  • Data Rates: 125 kbps, 250 kbps, 500 kbps

  • RPI (Requested Packet Interval): 5 ms minimum

  • Maximum TCP Connections: 30

  • Drive Electrical Consumption: 150 mA at 5V DC (supplied by host drive or DPI external kit)

  • Network Electrical Consumption: 60 mA at 24V DC (supplied by network)

  • LED Indicators: Three LEDs for drive, adapter, and network status

  • Operating Temperature: 10–50 °C (14–122 °F)

  • Storage Temperature: -40–85 °C (-40–185 °F)

  • Mounting Type: Panel mount (IP20, NEMA/UL Type 1 enclosure)

  • Weight: 0.19 lbs (0.09 kg)

Key Features

  • Seamless Integration: Enables DeviceNet connectivity for PowerFlex drives and motor controllers.

  • High-Speed Communication: Supports up to 500 kbps for fast data transfer.

  • Flexible Network Configuration: Adjustable baud rates and connection parameters.

  • Real-Time Control: 5 ms minimum RPI ensures precise, time-sensitive communication.

  • Status Feedback: Tri-color LED indicators provide at-a-glance network and adapter diagnostics.

  • Power Efficiency: Draws low current from both drive and DeviceNet network.

Application Scenarios

  • Factory Automation: Connect PowerFlex drives to DeviceNet networks for coordinated control.

  • Process Systems: Ideal for distributed control and motor coordination.

  • Material Handling: Supports synchronized drive communication for conveyors and packaging.

  • Energy Management: Enables efficient monitoring and control in multi-drive systems.

FAQs

Q: Which drives are compatible with the 20-COMM-D adapter?
A: It supports PowerFlex 70, 700, 700H, 700S, 700L, 750 drives, and SMC Flex/SMC-50 controllers.

Q: What is the supported communication speed?
A: The adapter operates at 125 kbps, 250 kbps, and 500 kbps.

Q: How many TCP connections are supported?
A: The adapter allows up to 30 simultaneous connections.

Q: What does the DC-OK LED indicate?
A: The LED indicators show communication, adapter, and drive connection status.

Q: Can it be mounted in any enclosure?
A: It is designed for panel mounting with IP20 and NEMA/UL Type 1 protection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more