Skip to content

What are you looking for?


You may also like

Allen-Bradley 1797-IE8NF FLEX Ex 8-Channel Intrinsically Safe Analog Input ModuleAllen-Bradley 1797-IE8NF FLEX Ex 8-Channel Intrinsically Safe Analog Input ModuleAllen-Bradley 1797-IE8NF FLEX Ex 8-Channel Intrinsically Safe Analog Input Module
Allen-Bradley 1797-IE8NF FLEX Ex 8-Channel Intrinsically Safe Analog Input Module
Allen-Bradley 1797-IE8NF FLEX Ex 8-Channel Intrinsically Safe Analog Input Module
Allen-Bradley 1797-IE8NF FLEX Ex 8-Channel Intrinsically Safe Analog Input Module

Allen-Bradley 1797-IE8NF FLEX Ex 8-Channel Intrinsically Safe Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1797-IE8NF

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1797-IE8NF functions as a high-precision interface for hazardous area instrumentation within the FLEX Ex I/O family. This module provides eight single-ended analog inputs designed specifically for mounting in Class I, II, III Division 1 & 2 locations. We supply this unit as 100% Brand New original factory stock. It features an integrated noise filter to ensure signal stability in high-interference environments, allowing for the direct connection of 4-20mA or 0-20mA field transmitters without the need for additional external barriers.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line FLEX Ex 1797
Number of Inputs 8 Single-ended, Non-isolated
Resolution 16 Bits
Hazardous Location Rating Class I, II, III Div 1 & 2; Groups A-G T4
Module Type Ex ib IIB/IIC T4 / AEx ib IIC T4
Integrated Noise Filter Included (Enhanced Signal Stability)
Step Response 4 Milliseconds
Power Dissipation 5.2 Watts
Field-side Power Consumption 7.5 Watts
Compatible Terminal Bases 1797-TB3 or 1797-TB3S
Keyswitch Position Position 3
Diagnostic Indicators 8 Red Fault LEDs, 1 Green Power LED

Engineering Advantages

  • Intrinsically Safe (IS) Design: The 1797-IE8NF eliminates the requirement for separate IS barriers or explosion-proof enclosures. The module's internal circuitry limits energy levels to prevent the ignition of flammable atmospheres, significantly reducing hardware costs and cabinet footprint in oil, gas, and chemical processing facilities.

  • Integrated Hardware Noise Filtering: The "NF" designation signifies advanced onboard filtering. This feature suppresses high-frequency electromagnetic interference (EMI) and crosstalk from nearby motor drives or power cables, providing clean 16-bit data to the controller in electrically noisy industrial environments.

  • Rapid Signal Processing: A 4 ms step response allows the module to capture fast-acting process variables. This low-latency performance ensures that the control system reacts instantly to pressure surges or flow fluctuations, maintaining tighter process loops and enhancing overall plant safety.

  • Comprehensive Fault Diagnostics: Eight dedicated red LEDs provide per-channel status monitoring. These indicators instantly alert technicians to wire-off conditions or sensor failures, facilitating rapid troubleshooting without the need to connect a laptop or open the control program.

  • High-Resolution Data Conversion: The 16-bit analog-to-digital converter transforms field signals into precise digital values. This granularity proves essential for applications requiring high accuracy, such as custody transfer or precision chemical dosing.

FAQs

  • Which terminal base must I use with the 1797-IE8NF?

    You must use the 1797-TB3 or 1797-TB3S terminal base. These bases provide the necessary termination points and physical mounting for the FLEX Ex module while maintaining IS circuit separation.

  • Does this module support HART communication?

    No. The 1797-IE8NF focuses on high-speed, filtered analog input processing. If your application requires HART protocol transparency for smart device diagnostics, you should consult the 1797-IE8H model.

  • What is the significance of Keyswitch Position 3?

    The keyswitch on the terminal base ensures that only the correct module type occupies the slot. Setting the base to Position 3 prevents accidental insertion of a different module type, which could otherwise compromise the intrinsic safety of the loop.

  • How do I verify the "Brand New" status of this unit?

    Every 1797-IE8NF arrives in its Original Factory-Sealed Packaging with the manufacturer's security label intact. As a new unit, the internal diagnostics register zero operation hours, and the gold backplane contacts remain free of any insertion marks, guaranteeing maximum service life in hazardous zones.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more