PRODUCT SKU : 1794-IR8

PRODUCT TYPE : RTD Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1794-IR8 is an eight-channel RTD input module designed for Flex I/O systems. It provides precise resistance temperature detector (RTD) measurement with high resolution and accuracy, supporting multiple terminal base units for flexible installation.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: Flex I/O

  • Part Number: 1794-IR8

  • Product Type: RTD Input Module

  • Number of Inputs: 8 channels

  • Module Location: Compatible with 1794-TB2, -TB3, -TB3S, -TB3T, -TB3TS terminal base units

  • Nominal Input Range: 1–433 ohms

  • RTD Excitation Current: 718.36 µA

  • Resolution: 16 bits across 435 ohms

  • Accuracy:

    • Normal mode: 0.05% full scale (max, without calibration)

    • Enhanced mode: 0.01% full scale (typical, low humidity)

  • Isolation Voltage: 850 V DC tested for 1 s (inputs and user power to logic side)

  • Data Format: 16-bit two’s complement or offset binary (unipolar)

  • Channel Bandwidth: 0–2.62 Hz (-3 dB)

  • Indicators: One red/green power status LED

  • Flexbus Current: 20 mA

  • Power Dissipation: 3.0 W max @ 31.2 V DC

  • Thermal Dissipation: 10.2 BTU/hr max @ 31.2 V DC

  • Weight: 1 kg

Features

  • Eight-channel RTD input capability for distributed temperature sensing

  • High accuracy with selectable normal and enhanced modes

  • Isolated channels for improved signal integrity

  • Compact Flex I/O design for modular installation

  • Diagnostic LED indicator for power status monitoring

Application Scenarios

  • Process Monitoring: Accurate RTD measurement for industrial temperature control

  • Distributed I/O Systems: Flexible integration with Flex I/O terminal bases

  • Legacy and Expansion Projects: Compatible with existing Flex I/O installations

FAQ

  • Q: How many input channels does the 1794-IR8 provide?  A: Eight RTD input channels.

  • Q: What terminal bases are supported?  A: 1794-TB2, -TB3, -TB3S, -TB3T, and -TB3TS.

  • Q: What is the accuracy of the module?  A: 0.05% full scale in normal mode, 0.01% typical in enhanced mode.

  • Q: Does the module provide isolation?  A: Yes, tested at 850 V DC for 1 second.

  • Q: How does this compare to the 1794-IR4?  A: The 1794-IR8 supports eight channels, while the 1794-IR4 provides four, making the IR8 suitable for higher-density applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential SCADA Features for Modern IoT-Enabled Industrial Automation

Essential SCADA Features for Modern IoT-Enabled Industrial Automation

The convergence of traditional SCADA systems with the Industrial Internet of Things (IIoT) has redefined factory automation. Choosing a robust platform requires more than just standard monitoring capabilities. In this era of Industry 4.0, your supervisory system must bridge the gap between legacy control systems and enterprise-level data integration.

Read more
Selecting Rockwell Automation Allen-Bradley PLCs for Small and Mid-Sized Applications

Selecting Rockwell Automation Allen-Bradley PLCs for Small and Mid-Sized Applications

Rockwell Automation remains a cornerstone in global industrial automation. Their Allen-Bradley brand provides a comprehensive portfolio of control systems designed to meet diverse production requirements. Choosing the right programmable logic controller (PLC) is critical for system reliability and scalability. This guide analyzes the Micro and Compact Logix families to help you select the optimal solution for small and medium-scale projects.

Read more
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more