Product Overview

The Allen-Bradley 1788-EN2FFR acts as a high-availability gateway bridging redundant EtherNet/IP networks with Foundation Fieldbus H1 segments. This network linking device features dual RJ45 EtherNet/IP connectors and two sets of H1 media terminals, ensuring seamless and fault-tolerant data exchange between modern control systems and field instruments. It operates on a 24-32V DC power supply and features an open-style chassis designed for standard DIN rail mounting. We supply this item as a 100% Brand New, factory-sealed unit.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Series 1788 Linking Devices
Product Type Network Linking Module / Telecom Adaptor
Network Interfaces Redundant EtherNet/IP to Foundation Fieldbus
EtherNet/IP Ports 2 x RJ45 Connectors
Fieldbus Terminals 2 x Sets of H1 Media Terminals
Input Power 24 - 32V DC
Enclosure Type Open Style
Mounting Method DIN Rail Mounted
Weight 1.20 lbs (0.54 kg)

Engineering Advantages

Redundant Network Architecture
The 1788-EN2FFR is engineered for mission-critical process automation environments. By supporting redundant EtherNet/IP connections alongside dual H1 media terminals, it eliminates single points of failure. If a primary network cable or switch fails, the module seamlessly maintains communication, ensuring your control system retains continuous visibility and command over field devices without costly downtime.

Seamless Protocol Bridging
This linking device efficiently translates high-speed EtherNet/IP traffic into Foundation Fieldbus H1 signals. It allows modern Logix-based controllers to easily integrate with legacy or specialized field instruments (such as smart transmitters and valve positioners) that operate on the Foundation Fieldbus protocol, simplifying your overall system architecture and reducing the need for multiple disparate gateways.

Standardized Industrial Installation
Designed for rapid deployment in control cabinets, the open-style module mounts directly onto a standard DIN rail. The clear terminal blocks for both the 24-32V DC power and the H1 media simplify wiring and troubleshooting. Its compact 1.20 lbs footprint conserves valuable panel space while delivering robust telecommunications adaptability.

FAQs

Q: What network protocols does the 1788-EN2FFR connect?
A: This module acts as a bridge between a redundant EtherNet/IP network (using dual RJ45 ports) and Foundation Fieldbus H1 segments (using two sets of H1 media terminals), allowing seamless data exchange between the two protocols.

Q: What is the power requirement for this linking module?
A: The 1788-EN2FFR requires a DC power supply ranging from 24 to 32 volts. Ensure your control panel provides a stable voltage within this range for optimal operation.

Q: How does this module improve network reliability?
A: It features built-in redundancy for both the EtherNet/IP and Foundation Fieldbus connections. This dual-path capability ensures that communication remains active even if one network link experiences a physical fault or interruption.

Q: How is the 1788-EN2FFR mounted in a control panel?
A: The module features an open-style industrial design that snaps directly onto a standard DIN rail, allowing for quick installation, secure mounting, and easy removal for maintenance or replacement.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more