Skip to content

What are you looking for?


You may also like

Allen-Bradley | 1783-ETAP1F 3-Port EtherNet/IP Tap 2 TP / 1 FiberAllen-Bradley | 1783-ETAP1F 3-Port EtherNet/IP Tap 2 TP / 1 FiberAllen-Bradley | 1783-ETAP1F 3-Port EtherNet/IP Tap 2 TP / 1 Fiber
Allen-Bradley | 1783-ETAP1F 3-Port EtherNet/IP Tap 2 TP / 1 Fiber
Allen-Bradley | 1783-ETAP1F 3-Port EtherNet/IP Tap 2 TP / 1 Fiber
Allen-Bradley | 1783-ETAP1F 3-Port EtherNet/IP Tap 2 TP / 1 Fiber

Allen-Bradley | 1783-ETAP1F 3-Port EtherNet/IP Tap 2 TP / 1 Fiber


Only 10 left - Selling fast

PRODUCT SKU : 1783-ETAP1F

PRODUCT TYPE : EtherNet/IP Tap Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1783-ETAP1F is a high-performance EtherNet/IP tap module designed to integrate seamlessly into industrial networks. It provides three ports—two twisted pair (TP) copper and one fiber—for reliable monitoring and network traffic management without disrupting communication.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model / Part Number: 1783-ETAP1F

  • Product Type: EtherNet/IP Tap Module

  • Ethernet Ports: 3 (2 copper TP, 1 fiber)

  • Tap Type: Copper

  • Max Current Consumption: 125 mA @ 24V DC

  • Power Supply Rating: 24V DC (20.4–27.6V DC), Class 2 / SELV

  • Isolation Voltage: 30V continuous; Type tested at 1250V DC for 60 seconds

  • Max Power Consumption / Dissipation: 3 W

  • Ethernet Connector: RJ45 (IEC 60603-7), supports Category 5e or Category 5 cabling

  • DC Power Connections:

    • One 0.33–3.3 mm² (22–12 AWG) solid/stranded copper wire

    • Or two 0.33–1.3 mm² (22–16 AWG) wires

    • Insulation max 1.2 mm; rated 75 °C or higher

  • Torque on Power Connectors: 0.6–0.8 N·m (5–7 lb·in)

  • Wiring Category: 1 for power, 2 for communication ports

  • Enclosure Type: Open-style (no enclosure)

  • Temperature Rating: North American / IEC code T5

Applications

  • Network traffic monitoring on EtherNet/IP industrial networks

  • Integration with control systems requiring fiber and copper connectivity

  • Diagnostics and troubleshooting of high-speed automation networks

FAQs

Q1: How many network ports are available on the 1783-ETAP1F?
It features three ports: two copper TP and one fiber for flexible connectivity.

Q2: What is the maximum power consumption?
The module consumes up to 3 W under normal operating conditions.

Q3: Is this module isolated?
Yes, it provides 30V continuous isolation and has passed 1250V DC type testing between network channels and power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more