Product Overview

The Allen-Bradley 1769-L18ER-BB1B serves as a core processing unit within the CompactLogix 5370 L1 family. This controller combines the functional power of the Logix engine with the modular flexibility of the 1734 POINT I/O system. It provides an ideal solution for small to medium-scale applications requiring high-speed integrated motion over EtherNet/IP and distributed control. We supply this controller as 100% Brand New and Original, ensuring your automation architecture utilizes the latest hardware revisions without the risks associated with surplus stock.

Technical Specifications

The 1769-L18ER-BB1B utilizes a built-in 24V DC power supply and supports high-density task management.

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Line: CompactLogix 5370 L1

  • User Memory: 512 KB

  • Local I/O Capacity: Supports up to 8 Bulletin 1734 POINT I/O Modules

  • Controller Tasks: 32 Tasks (1000 Programs per Task)

  • Communication Ports: Dual EtherNet/IP Ports

  • Network Topologies: DLR (Device Level Ring), Linear, and Star

  • Energy Storage: Internal (Eliminates the need for a battery)

  • Digital I/O Onboard: 16 Sink Inputs / 16 Source Outputs (24V DC)

  • Weight: 1.38 lbs (0.62 kg)

Engineering Advantages

  • Elimination of Battery Maintenance: The integrated energy storage module preserves the controller's memory during power loss. This design removes the need for lithium batteries, reducing scheduled maintenance costs and preventing potential data loss due to battery failure.

  • Network Redundancy with DLR: Dual Ethernet ports support Device Level Ring (DLR) technology. This allows the controller to detect and recover from a single point of failure in the network ring, maintaining system operation while technicians repair the damaged cable.

  • Compact Modular Scalability: The L1 series architecture accepts up to eight 1734 POINT I/O modules directly on the right side of the controller. This provides an exceptionally high I/O density in a narrow footprint, making it the perfect choice for crowded control cabinets or machine-mounted enclosures.

  • High-Performance Tasking: The controller manages up to 32 independent tasks. This multi-tasking capability ensures that time-critical motion or safety logic executes at high priority without interference from lower-priority background communication or diagnostic routines.

  • Unified Engineering Environment: The 1769-L18ER-BB1B integrates seamlessly with Studio 5000 Logix Designer. This allows engineers to use a single software platform for logic, motion, and safety configuration, accelerating the commissioning process.

FAQs

  • Does the 1769-L18ER-BB1B require a separate power supply?

    The controller features an integrated 24V DC power supply that powers the controller and the internal backplane for the local 1734 POINT I/O modules. You must provide a stable external 24V DC source to the "VDC" terminals of the unit.

  • Can I expand the I/O beyond the 8 local modules?

    Yes. While the local backplane supports up to 8 POINT I/O modules, you can expand the system by adding distributed I/O over the EtherNet/IP network. The controller communicates with remote 1734-AENTR or 1794-AENTR adapters to manage hundreds of additional I/O points.

  • Is this controller compatible with older RSLogix 5000 versions?

    The 1769-L18ER-BB1B generally requires Studio 5000 Logix Designer (Version 20 and higher). Always verify your specific firmware revision to ensure compatibility with your existing software licenses and hardware profiles.

  • What happens to my program if the power fails?

    The controller utilizes its internal energy storage to write the contents of its volatile memory to onboard non-volatile flash memory during a power-down event. This ensures your program and tag values remain intact upon the next power-up without requiring a battery backup.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more