PRODUCT SKU : 1769-IR6

PRODUCT TYPE : RTD / Resistance Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1769-IR6 is a Compact I/O RTD/Resistance Input Module designed for precise temperature and resistance measurement in industrial automation systems. It supports multiple sensor types and integrates seamlessly with CompactLogix and MicroLogix 1500 controllers.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line CompactLogix

  • Product Family Compact I/O

  • Part Number 1769-IR6

  • Weight 1.00 lbs (0.45 kg)

  • Product Type RTD / Resistance Input Module

  • Module Type RTD Module

  • Input Type Resistance

  • Number of Inputs 6

  • Sensors Supported Platinum 385 (100, 200, 500, 1000 Ω), Platinum 3916 (100, 200, 500, 1000 Ω), Nickel 672 (120 Ω), Nickel 618 (120 Ω), Nickel-Iron 518 (10 Ω)

  • Resistance Signals 150 Ω, 500 Ω, 1000 Ω, 3000 Ω

  • Communication Cable 6-point connection

  • Compatible Controllers CompactLogix, MicroLogix 1500

  • Current Draw @ 5.1V 100 mA

  • Current Draw @ 24V DC 35 mA

  • Series A and B

  • Heat Dissipation (Max) 1.5 W

  • Converter Type Sigma Delta

  • Nonlinearity ±0.05%

  • Repeatability (50/60 Hz filter) ±0.01 °C (Ni/NiFe), ±0.2 °C (other RTDs), ±0.04 Ω (150 Ω resistances), ±0.2 Ω (other resistances)

  • Wire Type Copper, rated 90 °C

  • Wire Size (Solid) 22 to 14 AWG

  • Open Circuit Detection Time 6 ms to 303 s

  • Recommended Cable

    • 2-wire: Belden 9501 or equivalent

    • 3-wire: Belden 9533 or equivalent

    • 4-wire: Belden 83503 or equivalent

  • Replacement Door Part Number 1769-RD

  • Replacement Door Label Part Number 1769-RL2 Series B

  • Replacement Terminal Block Part Number 1769-RTBN18

Application Scenarios

  • Precision temperature monitoring in industrial processes

  • Resistance measurement for specialized sensors

  • Integration with CompactLogix-based control systems

  • Suitable for environments requiring high repeatability and accuracy

FAQ

  • Q: Which controllers are compatible with this module?  A: CompactLogix and MicroLogix 1500 controllers.

  • Q: What sensor types are supported?  A: Platinum, Nickel, and Nickel-Iron sensors with multiple resistance ranges.

  • Q: What is the maximum heat dissipation?  A: 1.5 W.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more