Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input ModuleAllen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input ModuleAllen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module
Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module
Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module
Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module

Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IT61

PRODUCT TYPE : Isolated Thermocouple Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IT6I is a ControlLogix analog thermocouple input module featuring six isolated channels. It provides high-accuracy temperature measurement and flexible integration for industrial automation applications, supporting a wide range of thermocouple types.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Model / Part Number: 1756-IT6I

  • Product Type: 6-Point Isolated Thermocouple Input Module

  • Module Type: Analog Thermocouple Module (Isolated)

  • Number of Inputs: 6 isolated thermocouple channels + 1 CJC channel

  • Supported Thermocouples: B, C, E, J, K, N, R, S, T

  • Input Range: -12…78 mV (typical), -12…30 mV (high-resolution range)

  • Resolution: 16 bits, 0.7–1.4 µV/bit depending on input range

  • Data Format: Integer mode (left justified, 2’s complement), IEEE 32-bit floating point

  • Module Scan Time: 25 ms min floating point (millivolt), 50 ms min floating point (temperature), 10 ms min integer (millivolt)

  • Backplane Current: 5V DC: 250 mA, 24V DC: 125 mA

  • Power Dissipation: 4.3 W max

  • Removable Terminal Blocks: 1756-TBNH, 1756-TBSH

  • Enclosure Type: Open

  • Weight: 1.38 lbs (0.62 kg)

Key Features

  • Fully isolated inputs for accurate thermocouple measurement without cross-channel interference

  • Supports multiple thermocouple types for versatile process monitoring

  • High-resolution input for precision signal conversion

  • Compatible with ControlLogix chassis and removable terminal blocks for easy installation

  • Low power consumption and minimal heat generation

Application Scenarios

  • Industrial temperature monitoring and process automation requiring isolated thermocouple inputs

  • Integration with ControlLogix PLCs for precision process control

  • Multi-channel temperature acquisition for SCADA or HMI systems

  • Replacement or upgrade for existing 6-point TC modules in ControlLogix racks

FAQs

Q: How many thermocouple channels are isolated?
A: All six input channels are fully isolated for accurate measurements.

Q: Which thermocouple types are supported?
A: B, C, E, J, K, N, R, S, and T thermocouples are compatible.

Q: What is the module scan time?
A: Scan times range from 10 ms (integer millivolt) to 50 ms (floating point temperature) depending on configuration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more