Skip to content

What are you looking for?


You may also like

Allen-Bradley 1202-H90 SCANport Human Interface Module Cable KitAllen-Bradley 1202-H90 SCANport Human Interface Module Cable KitAllen-Bradley 1202-H90 SCANport Human Interface Module Cable Kit
Allen-Bradley 1202-H90 SCANport Human Interface Module Cable Kit
Allen-Bradley 1202-H90 SCANport Human Interface Module Cable Kit
Allen-Bradley 1202-H90 SCANport Human Interface Module Cable Kit

Allen-Bradley 1202-H90 SCANport Human Interface Module Cable Kit


Only 10 left - Selling fast

PRODUCT SKU : 1202-H90

PRODUCT TYPE : HIM Extension Cable

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1202-H90 delivers extended connectivity for industrial drive systems utilizing the SCANport interface. This 9-meter cable kit enables engineers to remotely mount a Human Interface Module (HIM) away from the variable frequency drive (VFD) enclosure. Featuring a durable male-to-female configuration, it ensures a secure and direct connection for programming, monitoring, and troubleshooting drive parameters. We supply this item as a 100% Brand New, factory-sealed unit.

Part Number Breakdown

  • 1202: Identifies the Allen-Bradley drive accessories and cable product family.

  • H: Denotes the accessory type (HIM / Human Interface Module cable).

  • 90: Specifies the cable length (9 meters).

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Type SCANport HIM Cable Kit
Cable Length 9 meters (approx. 29.5 feet)
Connector Type Male-to-Female
Interface Protocol SCANport
Compatible Equipment Drives supporting SCANport interface
Weight 1.87 lbs (0.85 kg)

Engineering Advantages

Extended Remote Mounting Capability
The 1202-H90 provides a generous 9-meter extension, allowing you to mount the Human Interface Module (HIM) in a highly visible and accessible location, even if the drive itself is installed in a hard-to-reach area, inside a locked cabinet, or high up on a machine frame. This flexibility significantly improves operational safety and ease of use for plant floor technicians.

Seamless SCANport Integration
Designed specifically for products supporting the SCANport interface, this cable ensures plug-and-play compatibility with Allen-Bradley drives and HIMs. The male-to-female connector design creates a direct passthrough link, maintaining full data integrity for drive configuration, status monitoring, and fault diagnostics without signal degradation over the extended distance.

Durable Industrial Construction
Built to withstand the rigors of daily industrial use, the cable kit features robust shielding and strain relief at the connection points. Its durable jacket protects the internal wiring from physical damage, oil, and typical factory floor contaminants, ensuring a long service life for your critical drive communication link.

FAQs

Q: What is the maximum length of the 1202-H90 cable?
A: This cable kit provides a total length of 9 meters (approximately 29.5 feet), which is ideal for extending a drive's HIM to a remote operator station or a more accessible panel door location.

Q: Which drives and modules are compatible with this cable?
A: The 1202-H90 is designed for use with any Allen-Bradley drive and Human Interface Module (HIM) that features a SCANport interface. It is commonly used with PowerFlex and other legacy drive families that support this communication standard.

Q: What type of connectors does this cable use?
A: The cable features a male-to-female connector configuration. This allows it to plug directly into the SCANport port on the drive, while the female end accepts the standard plug from the detachable HIM.

Q: Can I use this cable to connect a PC to the drive?
A: No. This cable is specifically engineered to connect a Human Interface Module (HIM) to a drive. For connecting a PC to a SCANport drive for programming, you would typically need a different interface converter, such as a 1203-USB or similar SCANport-to-USB/Serial adapter.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more