PRODUCT SKU : SNAT603CNT SNAT 603 CNT

PRODUCT TYPE : Control Board

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB SNAT603CNT SNAT 603 CNT is a control board for the AC800M series I/O modules, engineered for reliable operation in Class G3 (harsh) environments. Its compact and rugged design ensures consistent performance under challenging industrial conditions. This module is optimized for discrete input/output handling, providing galvanic isolation for safe and interference-free signal management.

Specifications

  • Brand/Manufacturer: ABB

  • Model/Part Number: SNAT603CNT SNAT 603 CNT

  • Alternate Part Numbers: UNS0880A-P, V11

  • Product Type: Control Board / I/O Module

  • Dimensions: 35 × 11.7 × 3 cm

  • Weight: 0.38 kg

  • Input/Output Voltage Support: 15–60 V DC, 120 V AC/DC, 240 V AC

  • Outputs: Eight discrete outputs

  • Isolation: Galvanically isolated inputs and outputs with group isolation for external excitation

  • Mounting Type: Enclosure or panel mounting compatible with AC800M systems

Features

  • Discrete I/O Support: Handles both DC and AC signals across multiple voltage levels.

  • Galvanic Isolation: Ensures signal integrity and protection from interference.

  • Rugged Design: Suitable for harsh Class G3 industrial environments.

  • Compact Footprint: Enables efficient integration into AC800M controller racks.

  • Reliable Operation: Designed for long-term stability in heavy-duty applications.

  • Flexible Connectivity: Compatible with a range of AC800M I/O modules and external excitation setups.

Applications

The SNAT603CNT is widely used in process automation and control systems, including power plants, chemical production, and industrial manufacturing where reliable signal processing and robust module protection are critical.

FAQ

Q1: Is the SNAT603CNT a genuine ABB product?
A1: Yes, all units are factory-sealed and fully new ABB components.

Q2: What environments can this control board operate in?
A2: It is designed for Class G3 harsh environments, handling temperature, vibration, and electrical stress reliably.

Q3: How many discrete outputs does this module have?
A3: It features eight discrete outputs with galvanic isolation.

Q4: Which AC800M modules is it compatible with?
A4: Compatible with standard AC800M I/O racks and modules requiring discrete signal control.

Q5: What are the physical dimensions and weight?
A5: The board measures 35 × 11.7 × 3 cm and weighs 0.38 kg.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more