Skip to content

What are you looking for?


You may also like

ABB AO890 3BSC690072R1 S800 I/O 8-Channel Intrinsically Safe Analog Output ModuleABB AO890 3BSC690072R1 S800 I/O 8-Channel Intrinsically Safe Analog Output ModuleABB AO890 3BSC690072R1 S800 I/O 8-Channel Intrinsically Safe Analog Output Module
ABB AO890 3BSC690072R1 S800 I/O 8-Channel Intrinsically Safe Analog Output Module
ABB AO890 3BSC690072R1 S800 I/O 8-Channel Intrinsically Safe Analog Output Module
ABB AO890 3BSC690072R1 S800 I/O 8-Channel Intrinsically Safe Analog Output Module

ABB AO890 3BSC690072R1 S800 I/O 8-Channel Intrinsically Safe Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : AO890 3BSC690072R1

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The AO890 is an intrinsically safe analog output module for actuators, positioners, and I/P converters in hazardous areas. With energy-limiting circuitry and bi-directional HART support, it enables safe, precise control and remote diagnostics. Ideal for petrochemical, pharmaceutical, and oil and gas applications.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Sweden

  • Model Number: AO890 (3BSC690072R1)

  • Output Configuration: 8 single-ended channels

  • Signal Range: 4 to 20 mA

  • Safety Rating: Intrinsically Safe (Ex ia)

  • D/A Resolution: 12 bits

  • HART Support: Bi-directional HART pass-through

  • Power Supply: 24 VDC nominal

  • Physical Weight: 0.25 kg (0.55 lbs)

  • Maximum Load: 750 ohms at 20 mA

Features

  • Direct Hazardous Area Connection: Built-in isolation barriers allow for direct wiring to Zone 0/1 devices, optimizing installation costs and footprint.

  • HART Digital Integration: Facilitates advanced device management and secondary variable monitoring via the control system.

  • Galvanic Isolation: Provides high-level isolation between the system electronics and the hazardous field environment to prevent surge damage.

  • Intelligent Safety Behavior: Supports programmable fail-safe modes to ensure actuators move to a designated safe position upon signal loss.

  • Output Current Supervision: Continuously monitors the health of the output loop to detect open circuits or field wiring faults.

  • Hot-Swap Support: Enables module replacement during live operation without compromising the safety integrity of the remaining I/O station.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Engineering MCC Signal Interface Terminations in Modern Process Automation

Engineering MCC Signal Interface Terminations in Modern Process Automation

Industrial manufacturing plants rely on Motor Control Centers (MCC) to drive critical electrical loads. Plant engineers must interface these MCC motor starters and drives with central control systems. Standardizing the Signal Interface Termination (SIT) architecture ensures seamless command delivery and feedback monitoring between field equipment and process automation platforms.

Read more
Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Modern factory automation relies heavily on robust Industrial Ethernet communications. Control system engineers deploy managed Ethernet switches to connect programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and field I/O devices. Selecting between Layer-2 and Layer-3 switching architecture directly impacts network throughput, routing capabilities, and overall cybersecurity defense in operational technology (OT) networks.

Read more
Understanding OpenTelemetry in Industrial Automation: Architecture, Observability, and Operational Benefits

Understanding OpenTelemetry in Industrial Automation: Architecture, Observability, and Operational Benefits

Modern industrial control systems (PLCs, DCS, edge nodes) are rapidly adopting cloud-native architectures, generating vast operational data. OpenTelemetry offers an open-source framework that unifies metrics, logs, and execution traces, enabling standardized observability across industrial automation and IT systems.

Read more