PRODUCT SKU : 5094-IF8

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 5094-IF8 functions as a high-density analog input gateway for the FLEX 5000 I/O platform. It provides 8 single-ended channels designed to interface with high-speed process transmitters and sensors. By utilizing dual 24-bit Sigma-Delta analog-to-digital converters, this module delivers elite-level precision and rapid data refresh rates for complex automation architectures. We offer this unit as 100% Brand New, ensuring factory-sealed integrity for your mission-critical control systems.

Technical Specifications

Feature Technical Data
Manufacturer Allen Bradley / Rockwell Automation
Product Line FLEX 5000
Inputs 8 Single-ended channels
Voltage Ranges $\pm 10\text{V}$$0-10\text{V}$$0-5\text{V}$
Current Ranges $0-20\text{mA}$$4-20\text{mA}$
Conversion Method Sigma-Delta (Two 24-bit multiplexed ADC)
Calibrated Accuracy $0.05\%$ full scale at $25\text{°C}$
Scan Time $625\text{\mu s}$ per channel / $2.5\text{ms}$ per module
Input Impedance Voltage: $>1\text{M\Omega}$ / Current: $250\text{\Omega}$ (typical)
Resolution Up to 16 bits (filter dependent)
Weight $0.31\text{lbs}$ ($0.14\text{kg}$)

Engineering Advantages

  • Ultra-High Precision Conversion: The integration of two 24-bit Sigma-Delta ADCs allows the module to resolve minute signal fluctuations. With a voltage resolution as fine as <80 \mu V/count, the 5094-IF8 captures highly granular data, making it ideal for precision pressure and flow monitoring.

  • Rapid Scan Performance: This module executes a full 8-channel scan in just 2.5 ms. This high-speed performance eliminates latency issues in fast-acting PID loops and ensures your controller receives real-time field data without bottlenecking.

  • Superior Thermal Stability: Industrial environments often face temperature fluctuations that drift analog readings. The 5094-IF8 maintains an impressive accuracy drift of only 28 ppm/ºC for voltage, ensuring consistent measurements from cold startups to peak operating temperatures.

  • Space-Efficient High Density: Providing 8 channels in a compact 0.31 lbs form factor optimizes cabinet rail space. This high density allows for more I/O points in a smaller footprint, reducing the need for additional expansion enclosures.

FAQs

  • Does the 5094-IF8 support mixed current and voltage inputs?

    Yes. You can configure each of the 8 channels independently for either voltage or current via the Studio 5000 Logix Designer software. This flexibility allows you to connect different transmitter types to a single module.

  • How does this module handle common mode noise between channels?

    The module supports a channel-to-channel common mode voltage of $\pm 10\text{V}$. This protects signal integrity when field devices operate at slightly different ground potentials, preventing cross-channel interference.

  • What is the benefit of the Sigma-Delta conversion method in this module?

    Sigma-Delta conversion provides excellent noise rejection and high resolution. It effectively filters out high-frequency industrial interference that often plagues standard SAR converters, ensuring a clean signal for your control logic.

  • Can I replace a legacy FLEX I/O module with the 5094-IF8?

    The 5094-IF8 belongs to the FLEX 5000 family, which requires a FLEX 5000 EtherNet/IP adapter. While it performs similar functions to the 1794 series, it offers significantly higher speeds and resolution and requires the corresponding FLEX 5000 mounting base.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more