Skip to content

What are you looking for?


You may also like

2711P-T7C4D1 | Allen-Bradley | PanelView Plus 700 Touchscreen HMI Terminal2711P-T7C4D1 | Allen-Bradley | PanelView Plus 700 Touchscreen HMI Terminal2711P-T7C4D1 | Allen-Bradley | PanelView Plus 700 Touchscreen HMI Terminal
2711P-T7C4D1 | Allen-Bradley | PanelView Plus 700 Touchscreen HMI Terminal
2711P-T7C4D1 | Allen-Bradley | PanelView Plus 700 Touchscreen HMI Terminal
2711P-T7C4D1 | Allen-Bradley | PanelView Plus 700 Touchscreen HMI Terminal

2711P-T7C4D1 | Allen-Bradley | PanelView Plus 700 Touchscreen HMI Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T7C4D1

PRODUCT TYPE : HMI Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 2711P-T7C4D1 is a high-performance operator interface belonging to the legacy PanelView Plus 700 series. Equipped with a 6.5-inch color display, this terminal provides a compact yet powerful visualization solution for machine-level monitoring. It features an analog resistive touchscreen for intuitive user interaction and is powered by a 24V DC input, making it suitable for integration into standard industrial control panels. While currently categorized as a discontinued product by the manufacturer, it remains a vital component for maintaining existing automated lines.

Technical Characteristics

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Model Number: 2711P-T7C4D1

  • Device Category: Operator Terminal / HMI

  • Display Technology: Color Active Matrix TFT LCD

  • Viewing Size: 6.5 inches (132 x 99 mm active area)

  • Screen Resolution: 640 x 480 VGA

  • Luminance/Backlight: CCFL with 50,000-hour minimum service life

  • Operator Input: Analog resistive touchscreen

  • Touch Durability: 1 million actuations at 10–110g force

  • System Memory: 64 MB Flash / 64 MB RAM

  • Input Voltage: 24V DC (operating range 18–32V DC)

  • Interface Ports: Integrated Ethernet (10/100 Mbps) and RS-232 Serial

  • Modular Compatibility: Supports additional modules for DH+, RIO, and DH-485

  • Supported Software: FactoryTalk View Machine Edition (ME)

  • Approximate Weight: 1.81 kg (4.00 lbs)

Operational Application

The 2711P-T7C4D1 is designed to bridge the gap between complex PLC data and operator control. Its modular architecture allows for the separate replacement of the display module, logic module, or communication interface, reducing long-term maintenance costs. This terminal is frequently found in food and beverage, packaging, and general manufacturing environments where a reliable, high-resolution interface is required to manage real-time process variables.

Frequently Asked Questions

What is the primary difference between the T7C and the K7C models?The 2711P-T7C4D1 is a touchscreen-only unit, whereas the K7C model relies on a physical keypad for user input. The touchscreen version offers a more flexible software-based interface layout.

Can this unit be powered by 120V AC?No, the 2711P-T7C4D1 is strictly a DC-powered terminal (18–32V DC). Attempting to provide AC power directly will result in hardware failure. An external power supply or an AC-to-DC logic module base is required.

Is the backlight replaceable?Yes, the CCFL backlight in the PanelView Plus 700 series is field-replaceable, allowing users to restore display brightness without replacing the entire unit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more