Skip to content

What are you looking for?


You may also like

2711P-T12W22D9P Allen-Bradley PanelView Plus 7 Performance Graphic Terminal2711P-T12W22D9P Allen-Bradley PanelView Plus 7 Performance Graphic Terminal2711P-T12W22D9P Allen-Bradley PanelView Plus 7 Performance Graphic Terminal
2711P-T12W22D9P Allen-Bradley PanelView Plus 7 Performance Graphic Terminal
2711P-T12W22D9P Allen-Bradley PanelView Plus 7 Performance Graphic Terminal
2711P-T12W22D9P Allen-Bradley PanelView Plus 7 Performance Graphic Terminal

2711P-T12W22D9P Allen-Bradley PanelView Plus 7 Performance Graphic Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T12W22D9P

PRODUCT TYPE : Graphic Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 2711P-T12W22D9P PanelView Plus 7 is a high-performance operator interface terminal designed for advanced visualization and control in industrial automation systems. Featuring a wide-format 12.1-inch color touchscreen, Ethernet DLR connectivity, and Windows CE operating system, it delivers robust functionality and flexibility for demanding applications.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line PanelView Plus 7 Performance Terminals

  • Part Number 2711P-T12W22D9P

  • Input Type Touchscreen (T)

  • Display Size 12.1 inches (12)

  • Display Type Wide aspect ratio color (W)

  • Network Connectivity Dual Ethernet DLR ports (22)

  • Power Supply 24 VDC (D)

  • Operating System Windows CE (9)

  • Model Type Performance (P)

  • Dimensions (L x W x H) 6.96 cm x 34 cm x 24 cm

  • Weight 2.54 kg

  • Mounting Panel mount design

Application Scenarios

  • Advanced machine-level operator interface with wide-format visualization

  • Industrial systems requiring Ethernet DLR redundancy for network reliability

  • Applications needing Windows CE compatibility for custom software integration

  • High-performance automation environments requiring responsive touchscreen input

FAQ

Q: What operating system does the 2711P-T12W22D9P run on?  A: It operates on Windows CE, supporting flexible application development.

Q: What type of network connectivity is available?  A: The terminal includes dual Ethernet DLR ports for redundant network configurations.

Q: Is this model part of the Performance series?  A: Yes, it belongs to the PanelView Plus 7 Performance line, offering enhanced functionality.

Comparison with Similar Models

  • 2711P-T12C4D8: Standard version with single Ethernet port and smaller feature set.

  • 2711P-T15W22D9P-B: Larger 15-inch wide-format display with similar performance features.

  • 2711P-T12W22D9P-B: Balanced option with 12.1-inch wide display, dual Ethernet, and Windows CE.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more