Product Details

Product Description

The 2711P-T12C4D1 (Part Number: 2711P-T12C4D1) serves as a high-performance Human Machine Interface (HMI) within the PanelView Plus 1250 series. This specific model features a 12.1-inch active-matrix color display, providing operators with a high-resolution graphical interface for complex machine monitoring. Designed for demanding industrial environments, it supports DC input power and utilizes a modular architecture, consisting of a dedicated display module and a logic module. Although currently classified as discontinued by the manufacturer, it remains a critical component for maintaining legacy control architectures in automotive, water treatment, and manufacturing sectors.

Detailed Technical Specifications

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Model Number: 2711P-T12C4D1

  • Product Series: PanelView Plus 1250

  • Display Technology: Color Active Matrix TFT LCD

  • Screen Size: 12.1-inch diagonal

  • Viewing Area: 246 x 184 mm (9.7 x 7.2 in.)

  • Display Resolution: 800 x 600 SVGA

  • Luminance: CCFL Backlight with 50,000-hour minimum half-life

  • Operator Input: Analog Resistive Touchscreen

  • Touch Durability: 1 million actuations at 10 to 110 grams of force

  • System Memory: 64 MB Flash / 64 MB RAM

  • External Storage: Support for Type 1 CompactFlash cards

  • Input Voltage: 24V DC (Operational range 18 to 32V DC)

  • Power Consumption: 70 Watts maximum (2.9A at 24V DC)

  • Onboard Communication: Integrated RS-232, Ethernet, and USB ports

  • Extended Networking: Support for DH+, Remote I/O (RIO), and DH-485 via communication modules

  • Operating Temperature: 0 to 55 °C (32 to 131 °F)

  • Internal Components: Includes Logic Module 2711P-RP1 and Display Module 2711P-RDT12C

Application Compatibility and Support FAQ

Which software is required to program this terminal?The 2711P-T12C4D1 is programmed using FactoryTalk View Studio Machine Edition (ME) software. Because this is a legacy PanelView Plus unit, users should ensure their software version supports the older firmware revisions typically found on these devices.

What is the difference between the 2711P-T12C4D1 and the 2711P-T12C4A1?The primary distinction lies in the input power. The 2711P-T12C4D1 (Part Number: 2711P-T12C4D1) is powered by a 24V DC source, whereas the "A1" suffix denotes a 120/240V AC power supply. They are functionally identical in terms of display and communication capabilities but cannot be interchanged without wiring modifications.

Is it possible to replace the backlight on this unit?Yes. Unlike many modern integrated displays, the PanelView Plus 1250 series utilizes replaceable CCFL backlights. If the screen is dark but the status LEDs indicate the logic is running, replacing the backlight assembly can often restore the unit to full operation.


 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more