PRODUCT SKU : 2711P-T10C4D2

PRODUCT TYPE : Operator Interface Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

Allen-Bradley PanelView Plus 1000 Operator Terminal – Model: 2711P-T10C4D2  The 2711P-T10C4D2 is a discontinued operator interface terminal from the Allen-Bradley PanelView Plus 1000 series. It features a 10.4-inch color TFT LCD display with touchscreen input, designed for industrial visualization and operator control. With multiple integrated communication ports and robust memory capacity, this terminal provided versatile connectivity and reliable performance in automation environments.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Product Line: PanelView Plus 1000

  • Model: 2711P-T10C4D2

  • Type: Operator Interface Terminal

  • Display Size: 10.4 inches

  • Display Area: 211 × 158 mm (8.3 × 6.2 in.)

  • Resolution: 640 × 480 pixels

  • Display Type: Color active matrix TFT LCD

  • Backlight: CCFL, minimum 50,000 hours life

  • Input Method: Touchscreen (rated for 1 million actuations, 10–110 g force)

  • Internal Memory: 128 MB Flash / 128 MB RAM

  • Communication Ports: Ethernet, Data Highway Plus (DH+), Remote I/O (RIO), DH485, RS-232, USB

  • Input Voltage Range: 18–32 VDC

  • Weight: 6.00 lbs (2.72 kg)

  • Series Compatibility: A, B, C, D, F

  • Lifecycle Status: Discontinued/Obsolete

Application Scenarios

  • Legacy PanelView Plus 1000 installations requiring touchscreen operator input

  • Machine-level visualization with multiple communication protocols

  • Industrial systems needing color display terminals with Ethernet and RS-232 connectivity

  • Replacement in discontinued PanelView Plus 1000 setups

FAQ

Q: What is the display resolution of the 2711P-T10C4D2?  A: 640 × 480 pixels.

Q: What input method does it support?  A: Touchscreen input with 1 million press durability.

Q: What communication options are available?  A: Ethernet, DH+, RIO, DH485, RS-232, and USB ports.

Q: Is this model still in production?  A: No, it is discontinued/obsolete.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more