Skip to content

What are you looking for?


You may also like

2711P-B7C4D8 | Allen-Bradley PanelView Plus 7 Standard HMI2711P-B7C4D8 | Allen-Bradley PanelView Plus 7 Standard HMI2711P-B7C4D8 | Allen-Bradley PanelView Plus 7 Standard HMI
2711P-B7C4D8 | Allen-Bradley PanelView Plus 7 Standard HMI
2711P-B7C4D8 | Allen-Bradley PanelView Plus 7 Standard HMI
2711P-B7C4D8 | Allen-Bradley PanelView Plus 7 Standard HMI

2711P-B7C4D8 | Allen-Bradley PanelView Plus 7 Standard HMI


Only 10 left - Selling fast

PRODUCT SKU : 2711P-B7C4D8

PRODUCT TYPE : HMI

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 2711P-B7C4D8 delivers a versatile operator interface for machine-level control. This PanelView Plus 7 Standard terminal combines a 7-inch color TFT display with both touchscreen and keypad inputs. It runs on a 1 GHz processor with Windows CE 6.0, handling complex visualization and data logging tasks. The unit accepts 18-32 VDC power, making it ideal for mobile equipment and low-voltage control panels. We supply this item as a 100% Brand New, factory-sealed unit.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Line PanelView Plus 7 Standard
Display 7-inch Color TFT (640 x 480)
Input Method Touchscreen + Keypad
Processor 1 GHz
Memory 512 MB RAM / 512 MB Flash
Communication Ethernet, RS-232, 2x USB
Power Supply 18-32 VDC
Enclosure Rating NEMA 4X, 12, IP65 (Front Panel)

Engineering Advantages

Hybrid Input for Operational Flexibility
This terminal integrates a physical keypad alongside the touchscreen. Operators can navigate menus and enter data using tactile buttons, which is essential when wearing gloves or working in high-vibration areas where touch accuracy drops. The keypad ensures precise control over critical parameters without accidental screen touches.

Ruggedized for Harsh Environments
The front panel meets NEMA 4X, 12, and IP65 standards. This sealing protects the display from washdowns, oil, dust, and water jets. You can mount this unit directly on food processing lines or in dusty cement plants without fearing ingress damage. The wide operating temperature range (0°C to 55°C) further ensures stability in unheated or hot industrial facilities.

DC Power and Connectivity
The 18-32 VDC power input aligns perfectly with standard 24V industrial control systems. This eliminates the need for separate AC transformers, simplifying panel wiring. Connectivity is robust, featuring Ethernet for high-speed PLC communication, RS-232 for legacy devices or printers, and two USB ports for memory stick data logging or peripheral connections.

FAQs

Q: What software is required to program the 2711P-B7C4D8?
A: You need RSView Studio (FactoryTalk View ME) to create applications for this terminal. It runs on the Windows CE 6.0 operating system, which supports the standard PanelView Plus runtime environment.

Q: Can I use this HMI with a 120V AC power source?
A: No. The "D8" suffix indicates this unit is designed strictly for 18-32 VDC input. Connecting it to an AC source will damage the internal power supply. Ensure your panel provides a regulated 24V DC supply.

Q: Does the keypad interfere with the touchscreen?
A: No. The design allows for simultaneous use or independent operation. You can configure the application to use the keypad for specific functions (like numeric entry) while using the touchscreen for navigation, maximizing operator efficiency.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more