Skip to content

What are you looking for?


You may also like

2711-K10C8 | Allen-Bradley PanelView 1000 Color Keypad Operator Terminal2711-K10C8 | Allen-Bradley PanelView 1000 Color Keypad Operator Terminal2711-K10C8 | Allen-Bradley PanelView 1000 Color Keypad Operator Terminal
2711-K10C8 | Allen-Bradley PanelView 1000 Color Keypad Operator Terminal
2711-K10C8 | Allen-Bradley PanelView 1000 Color Keypad Operator Terminal
2711-K10C8 | Allen-Bradley PanelView 1000 Color Keypad Operator Terminal

2711-K10C8 | Allen-Bradley PanelView 1000 Color Keypad Operator Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711-K10C8

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 2711-K10C8 is a PanelView 1000 Standard Operator Terminal designed for industrial machine control and monitoring. It provides a reliable human-machine interface with a color display and keypad input, offering seamless communication with Allen-Bradley PLC systems via DH+ and DH-485 networks.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PanelView Standard Terminals

  • Part Number: 2711-K10C8

  • Display Type: 10.4-inch color active matrix TFT LCD

  • Display Resolution: 640 x 480 pixels (VGA)

  • Display Area: 211 x 158 mm (8.3 x 6.2 in.)

  • Input Type: Keypad (numeric and function keys)

  • Backlight: Replaceable CCFL, rated 50,000 hours at 25°C

  • Communication Ports: DH+, DH-485

  • Input Voltage: 18–32V DC (nominal 24V DC)

  • Memory: 240 KB nonvolatile memory, 170 KB runtime application memory

  • Communication Cable: 2711-NC13 (optional)

  • Enclosure Rating: NEMA Type 12/13/4X, IP65 (indoor use)

  • Operating Temperature: 0–55°C (32–131°F)

  • Power Consumption: 70 VA max

  • Mounting Type: Panel mount

  • Weight: 6.6 lbs (3 kg)

Key Features

  • Keypad Input Interface: Durable tactile keypad with programmable function keys (F1–F10).

  • Color Display: 10.4-inch VGA display supports vivid graphical visualization of process data.

  • Flexible Communication: Dual-channel DH+ and DH-485 communication for system integration.

  • Rugged Design: Built for industrial conditions, compliant with NEMA and IEC protection standards.

  • Easy Replacement and Maintenance: Field-replaceable backlight and accessible terminal connections.

  • Efficient Power Use: Operates on 24V DC with minimal power draw.

Application Scenarios

  • Manufacturing Automation: Visual monitoring and operator control of production lines.

  • Process Control Systems: Interfaces with PLCs for real-time feedback and parameter adjustments.

  • Material Handling Equipment: Supervises conveyor, packaging, or batching operations.

  • Utilities and Infrastructure: Ideal for water treatment, energy monitoring, and building management.

FAQs

Q: What is the display size of the 2711-K10C8?
A: The terminal features a 10.4-inch color VGA display.

Q: What communication protocols are supported?
A: DH+ and DH-485 communication interfaces are supported.

Q: Does the terminal include touch input?
A: No, it uses a keypad input with function keys instead of a touchscreen.

Q: Is the backlight replaceable?
A: Yes, the CCFL backlight is field-replaceable.

Q: What is the operating voltage range?
A: The module operates between 18 and 32 volts DC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more