Only 10 left - Selling fast

PRODUCT SKU : 1794-OM8

PRODUCT TYPE : AC Digital Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1794-OM8 serves as a high-performance discrete output component within the FLEX I/O family. This module interfaces the controller with high-voltage AC field devices, providing 8 isolated points to switch actuators, motor starters, and solenoids. We supply this module as 100% Brand New and Factory Original, ensuring the internal triac circuitry meets the highest industrial standards for longevity and switching precision in distributed control architectures.

Technical Specifications

The 1794-OM8 converts digital logic signals into 220V AC power switching via the following technical parameters:

Feature Specification
Number of Outputs 8 Non-Isolated Outputs
Output Type Discrete AC (Triac)
Nominal Voltage 220V AC
Voltage Range 159V AC to 264V AC
Output Current Rating 1.0 A per channel (4.0 A per module max)
On-State Voltage Drop 1.0V @ 0.5 A (Maximum)
Off-State Leakage 2.5 mA (Maximum)
Mounting Configuration Horizontal or Vertical DIN Rail
Weight 1.87 lbs (0.85 kg)

Engineering Advantages

  • Modular Distributed Architecture: The 1794-OM8 plugs into a terminal base, separating the wiring from the I/O electronics. This design allows technicians to replace the module without disturbing field wiring, drastically reducing Mean Time to Repair (MTTR) during plant maintenance.

  • Space-Saving DIN-Mount Profile: The compact "Open Style" chassis minimizes panel footprint. By utilizing the FLEX I/O system, engineers consolidate high-voltage AC switching into tight enclosures where traditional rack-based PLCs cannot fit.

  • Robust 220V AC Switching: The integrated triac outputs handle a broad voltage range up to 264V AC. This resilience ensures stable operation in regions with fluctuating power grids or in heavy industrial zones where inductive loads cause significant line noise.

  • Passive Cooling Design: The module utilizes an efficient thermal layout that dissipates heat without the need for active fans. This reduces the risk of failure in dust-prone environments and allows for dense module packing on a single DIN rail.

FAQs

  • Is this 1794-OM8 unit genuinely brand new?

    Yes. We guarantee this unit is 100% Brand New and ships in its original Allen Bradley factory packaging. It has never seen service, ensuring the internal electronic components have no thermal wear or previous load history.

  • Which terminal base is compatible with the 1794-OM8?

    The 1794-OM8 requires a compatible FLEX I/O terminal base, such as the 1794-TB2, 1794-TB3, or 1794-TB3S. You must match the terminal base to your specific wiring requirements (screw vs. spring clamp).

  • Does the module support 110V AC applications?

    While the module is optimized for 220V AC, it operates within a range of 159V to 264V AC. For standard 120V AC applications, you should use the 1794-OM16 or 1794-OA8 to ensure the gate trigger voltages remain within manufacturer specifications.

  • How does the module handle inductive load spikes?

    The 1794-OM8 includes internal RC snubber circuits to suppress voltage transients. However, for highly inductive loads like large solenoids, we recommend installing external suppression across the load to further protect the module’s output triacs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more