Skip to content

What are you looking for?


You may also like

1794-IB16XOB16P | Allen Bradley Flex I/O 24V DC Digital Input/Output Module1794-IB16XOB16P | Allen Bradley Flex I/O 24V DC Digital Input/Output Module1794-IB16XOB16P | Allen Bradley Flex I/O 24V DC Digital Input/Output Module
1794-IB16XOB16P | Allen Bradley Flex I/O 24V DC Digital Input/Output Module
1794-IB16XOB16P | Allen Bradley Flex I/O 24V DC Digital Input/Output Module
1794-IB16XOB16P | Allen Bradley Flex I/O 24V DC Digital Input/Output Module

1794-IB16XOB16P | Allen Bradley Flex I/O 24V DC Digital Input/Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-IB16XOB16P

PRODUCT TYPE : Digital Input/Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1794-IB16XOB16P functions as a high-density distributed I/O solution within the Flex I/O 1794 ecosystem. This module integrates 16 sinking inputs and 16 sourcing outputs into a single, compact footprint, effectively doubling the control capacity without increasing rail space. We supply this unit as 100% Brand New original factory stock, ensuring maximum MTBF (Mean Time Between Failures) for your mission-critical automation loops.

Technical Specifications

Feature Specification
Manufacturer Allen Bradley / Rockwell Automation
Product Line Flex I/O 1794
I/O Count 32-Point (16 Input / 16 Output)
Voltage Category 24V DC
Output Type Sourcing, Electronically Protected
Input Type Sinking
Power Consumption 125 Watts (Maximum)
Enclosure Rating IP20 (NEMA Type 1)
Mounting Options DIN-Rail or Panel Mount
Weight 0.25 lbs (0.11 kg)

Engineering Advantages

  • Space-Efficient Density: By combining 32 channels of digital I/O on a single terminal base, this module slashes cabinet space requirements. It allows engineers to scale complex systems in overcrowded control rooms where panel real estate carries a premium.

  • Integrated Electronic Protection: The 1794-IB16XOB16P features built-in electronic protection for its sourcing outputs. This circuitry detects short circuits and overload conditions instantly, shutting down the affected channel to prevent catastrophic damage to the module or the connected field devices.

  • Versatile Installation: The module snaps directly onto a DIN-rail or bolts onto a backplane. This flexibility simplifies retrofitting older machines or building new, modular skid-based systems.

  • Reduced Wiring Complexity: Utilizing the Flex I/O architecture enables the separation of terminal wiring from the module itself. Maintenance teams can replace the 1794-IB16XOB16P without disconnecting field wires, drastically reducing downtime during hardware swaps.

FAQs

  • Does the 1794-IB16XOB16P require a separate terminal base?

    Yes. You must install the module onto a compatible 1794 terminal base (such as the 1794-TB3 or 1794-TB3S) to facilitate field wiring and connection to the FlexBus.

  • How does the electronic protection handle an output fault?

    The module identifies an overcurrent or short-circuit event and disables the specific output point. Once you resolve the external fault, the module resumes normal operation, eliminating the need for external fuses in most standard applications.

  • Can I use this module with different communication adapters?

    Absolutely. The 1794-IB16XOB16P maintains full compatibility with the entire range of 1794 adapters, including EtherNet/IP, ControlNet, and DeviceNet versions.

  • Is this unit factory-sealed?

    Yes. We guarantee this product is 100% Brand New, arriving in original manufacturer packaging with all factory seals intact to meet strict E-E-A-T quality standards.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more