Skip to content

What are you looking for?


You may also like

1783-US03T01F | Allen Bradley | Stratix 2000 Unmanaged Ethernet Switch1783-US03T01F | Allen Bradley | Stratix 2000 Unmanaged Ethernet Switch1783-US03T01F | Allen Bradley | Stratix 2000 Unmanaged Ethernet Switch
1783-US03T01F | Allen Bradley | Stratix 2000 Unmanaged Ethernet Switch
1783-US03T01F | Allen Bradley | Stratix 2000 Unmanaged Ethernet Switch
1783-US03T01F | Allen Bradley | Stratix 2000 Unmanaged Ethernet Switch

1783-US03T01F | Allen Bradley | Stratix 2000 Unmanaged Ethernet Switch


Only 10 left - Selling fast

PRODUCT SKU : 1783-US03T01F

PRODUCT TYPE : Ethernet Switch

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1783-US03T01F serves as a rugged, industrial-grade Ethernet switch within the Stratix 2000™ series. This unmanaged switch provides a seamless transition between traditional copper-based networks and fiber optic backbones, allowing for extended communication distances in complex automation environments. We supply this unit as 100% brand new and original, ensuring your network infrastructure benefits from factory-certified performance and long-term durability.

Technical Specifications

The 1783-US03T01F combines high-speed data transmission with robust electrical protection:

Feature Specification
Port Configuration 3 Copper (RJ45), 1 Fiber Optic
Ethernet Data Rate 100 Mbps (Fast Ethernet)
Input Voltage 20V AC / 24V DC
Inrush Current 2.2 Amperes
Isolation Voltage 30 Volts
Fiber Optical Budget 62.5/125 Multi-mode
Net Weight 1.06 lbs (0.48 kg)
UPC 612598349975

Engineering Advantages

  • Hybrid Connectivity Solution: The integration of three copper ports and one fiber port solves the challenge of long-distance signal attenuation. The fiber link allows the 1783-US03T01F to transmit data across hundreds of meters without the 100-meter limitation of standard CAT5e/6 cables.

  • Electromagnetic Interference (EMI) Immunity: By utilizing a fiber optic uplink, this switch isolates the network backbone from industrial noise, motor EMI, and ground loops that often disrupt electrical signals in manufacturing plants.

  • Versatile Power Input: The module accepts both 20V AC and 24V DC power sources. This flexibility allows engineers to integrate the switch into various control cabinet architectures without requiring dedicated power converters.

  • Compact Plug-and-Play Design: As an unmanaged switch, the 1783-US03T01F requires zero software configuration. It identifies connected devices automatically, significantly reducing commissioning time for small-to-medium scale machine networks.

  • Rugged Industrial Build: With a weight of 1.06 lbs and a robust housing, this switch withstands the vibration and thermal stresses typical of PLC racks. It meets strict UL and CE standards for global industrial deployment.

FAQs

  • What type of fiber cable does the 1783-US03T01F require?

    This switch supports 62.5/125 micron multi-mode fiber. Ensure your cable terminations match the optical link budget to maintain signal integrity over long distances.

  • Is this a managed or unmanaged switch?

    The 1783-US03T01F is an unmanaged switch. It provides a simple, "set-and-forget" networking solution that does not require IP address assignment or complex VLAN configuration.

  • Is this product a brand new Allen Bradley original?

    Absolutely. We guarantee that every 1783-US03T01F unit we ship is 100% brand new in original factory packaging with a verified UPC (612598349975). We do not deal in refurbished or used hardware.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more