Product Description

The Allen-Bradley 1763-L16BWA MicroLogix 1100 is a compact programmable controller designed for small to mid-range automation tasks. It provides 16 I/O points, integrated analog inputs, relay outputs, and built-in communication ports for flexible connectivity. With non-volatile memory and LCD display, it offers reliable control and monitoring in industrial environments.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line MicroLogix 1100

  • Product Type Programmable Controller (PLC)

  • Part Number 1763-L16BWA

  • Weight 1.31 lbs (0.60 kg)

  • Input Power 120–240 VAC

  • Point Count 16 I/O points

  • Digital Inputs 24 VDC sink/source (standard and high-speed)

  • Analog Inputs 2 voltage inputs (0–10 VDC)

  • Analog Resolution 10-bit unsigned integer

  • Digital Outputs 6 relay outputs

  • Communication Ports 1 RS-232/485, 1 Ethernet port

  • Display Integrated LCD for monitoring and configuration

  • Memory Non-volatile battery-backed RAM

  • Operating Frequency 47–63 Hz

  • Shock Resistance 10 G operating, 20 G non-operating

  • Dimensions (L x W x H) 7.87 x 1.57 x 3.15 inches

Application Scenarios

  • Small machine control requiring relay outputs and analog monitoring

  • Distributed automation systems with Ethernet and RS-232/485 communication

  • OEM equipment needing compact PLCs with integrated display

  • Legacy installations where MicroLogix 1100 controllers are still in use

FAQ

Q: How many I/O points does the 1763-L16BWA provide?  A: It provides 16 points, including 20 digital inputs and 6 relay outputs.

Q: What communication options are available?  A: RS-232/485 and Ethernet ports are included.

Q: Does the controller have an integrated display?  A: Yes, it features an LCD for monitoring and configuration.

Comparison with Similar Models

  • 1761-L32BWB (MicroLogix 1000): Earlier generation with fewer communication options.

  • 1763-L16BWA (MicroLogix 1100): Adds Ethernet connectivity and LCD display.

  • 1766-L32BXB (MicroLogix 1400): Expanded I/O and enhanced communication features.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more