Skip to content

What are you looking for?


You may also like

1756-OW16IK | Allen Bradley | ControlLogix 16-Point Isolated Relay Output Module1756-OW16IK | Allen Bradley | ControlLogix 16-Point Isolated Relay Output Module1756-OW16IK | Allen Bradley | ControlLogix 16-Point Isolated Relay Output Module
1756-OW16IK | Allen Bradley | ControlLogix 16-Point Isolated Relay Output Module
1756-OW16IK | Allen Bradley | ControlLogix 16-Point Isolated Relay Output Module
1756-OW16IK | Allen Bradley | ControlLogix 16-Point Isolated Relay Output Module

1756-OW16IK | Allen Bradley | ControlLogix 16-Point Isolated Relay Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-OW16IK

PRODUCT TYPE : Relay Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1756-OW16IK serves as a high-density, individually isolated relay output module for the ControlLogix platform. This module provides 16 independent N.O. (Normally Open) contacts, allowing the control system to switch diverse load voltages and polarities within a single chassis slot. The "K" suffix indicates a conformal coating, which protects the internal circuitry from corrosive atmospheric contaminants. We supply this unit as 100% Brand New original factory equipment, ensuring maximum contact life and circuit integrity for your mission-critical switching applications.

Technical Specifications

Feature Technical Data
Manufacturer Allen Bradley / Rockwell Automation
Module Type Isolated Relay Output (Conformal Coated)
Number of Outputs 16 Individually Isolated Points
Operating Voltage Range 10–265V AC / 5–150V DC
Output Current (Max) 2A @ 120V AC, 0.5A @ 240V AC, 0.25A @ 150V DC
Output Delay Time (Max) 10 ms (On/Off)
Contact Configuration Normally Open (N.O.)
Backplane Current 150mA @ 5.1V / 150mA @ 24V
Power Dissipation 4.5 Watts @ 60°C
Isolation Voltage 250V (Continuous)
Compatible RTB 1756-TBCH, 1756-TBS6H

Engineering Advantages

  • Individual Channel Isolation: Each of the 16 outputs maintains electrical isolation from the others. This architecture permits the simultaneous control of multiple voltage sources (e.g., mixing 120V AC and 24V DC) on one module, eliminating the need for interposing relays and reducing panel space requirements.

  • Conformal Coating (K-Suffix): The specialized protective coating shields the PCB from moisture, salt spray, and chemical vapors. This makes the 1756-OW16IK the ideal choice for wastewater treatment, oil and gas, and chemical processing facilities where standard modules might suffer from premature corrosion.

  • Broad Voltage Versatility: This module switches a wide operating range, from low-voltage 5V DC logic up to 265V AC power circuits. The relays handle diverse loads including solenoids, motor starters, and indicators, providing a universal interface for field devices.

  • Integrated Diagnostics: The module reports field-side power status and point-level state to the controller. This real-time feedback accelerates troubleshooting by identifying blown fuses or power losses directly through the Studio 5000 software interface.

FAQs

  • Can the 1756-OW16IK replace a standard 1756-OW16I module?

    Yes. The 1756-OW16IK functions exactly like the 1756-OW16I but adds conformal coating for environmental protection. It utilizes the same profile in Studio 5000, allowing for a direct physical and logical drop-in replacement.

  • Which Removable Terminal Block (RTB) should I use?

    This module requires a 36-pin RTB. You can use the 1756-TBCH (Cage Clamp) for secure manual wiring or the 1756-TBS6H (Spring Clamp) for high-vibration environments where screw-less termination is preferred.

  • Does this module support "Normally Closed" (N.C.) configurations?

    The 1756-OW16IK provides Normally Open (N.O.) contacts only. If your application requires N.C. logic, you must handle the inversion within the PLC ladder logic or utilize an external interposing relay.

  • What is the condition of this hardware?

    Every 1756-OW16IK we ship is 100% Brand New, original, and remains in its factory-sealed Allen Bradley packaging. We do not sell refurbished or surplus used equipment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more