Skip to content

What are you looking for?


You may also like

1756-M16SE | Allen-Bradley | ControlLogix 16-Axis SERCOS Interface Motion Module1756-M16SE | Allen-Bradley | ControlLogix 16-Axis SERCOS Interface Motion Module1756-M16SE | Allen-Bradley | ControlLogix 16-Axis SERCOS Interface Motion Module
1756-M16SE | Allen-Bradley | ControlLogix 16-Axis SERCOS Interface Motion Module
1756-M16SE | Allen-Bradley | ControlLogix 16-Axis SERCOS Interface Motion Module
1756-M16SE | Allen-Bradley | ControlLogix 16-Axis SERCOS Interface Motion Module

1756-M16SE | Allen-Bradley | ControlLogix 16-Axis SERCOS Interface Motion Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-M16SE

PRODUCT TYPE : ControlLogix Motion Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 1756-M16SE is a high-performance motion control module designed for the Allen-Bradley ControlLogix platform, providing a specialized interface for SERCOS (Serial Real-time Communication System) fiber-optic networks. This module serves as a centralized controller for high-speed, synchronized motion, capable of managing up to 16 axes of independent or coordinated motion per module. By utilizing digital fiber-optic rings, it eliminates traditional analog noise issues and significantly simplifies field wiring to Kinetix or other SERCOS-enabled drives.

As a core component of high-order motion architectures, the 1756-M16SE (Part Number: 1756-M16SE) supports data rates of 4 or 8 Mbps, ensuring precise closed-loop control. It is designed for seamless integration into 1756 ControlLogix chassis, drawing power directly from the backplane while maintaining continuous 50V isolation to protect the logic circuitry from external electrical noise.

Technical Specifications

  • Brand: Allen-Bradley

  • Model Designation: 1756-M16SE

  • Module Type: SERCOS interface motion module

  • Axis Capacity: 16 axes per module (System supports up to 32 axes per controller)

  • Communication Media: Plastic fiber-optic cable (2090-SCEP, 2090-SCVP, or 2090-SCNP)

  • Data Transfer Rates: 4 Mbps or 8 Mbps

  • Backplane Power Consumption: 760 mA @ 5.1V DC; 2.5 mA @ 24V DC

  • Power Dissipation: 6.2 Watts

  • Thermal Output: 21.2 BTU per hour

  • Continuous Isolation Voltage: 50 Volts

  • Chassis Compatibility: 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17

  • Standard Power Supplies: 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75

  • Redundant Power Supplies: 1756-PA75R, 1756-PB75R, 1756-PSCA2

Applications and Motion Performance

This module is ideally suited for complex packaging machinery, robotic assembly cells, and high-speed material handling systems where precise synchronization between multiple axes is paramount. The SERCOS digital interface ensures that drive parameters can be configured and monitored directly through Studio 5000 Logix Designer software, reducing commissioning time and improving diagnostic visibility.

Engineering FAQ

What fiber-optic cables are recommended for the 1756-M16SE?The module is compatible with 2090-series plastic fiber-optic cables. For standard environments, the 2090-SCVP standard jacket is sufficient, while the 2090-SCNP nylon jacket is recommended for applications requiring higher chemical or abrasion resistance.

Can the 1756-M16SE be used in a remote I/O chassis?No, motion modules must reside in the local chassis with the Logix controller to maintain the high-speed timing required for motion group synchronization and task execution.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more