Skip to content

What are you looking for?


You may also like

1756-IM16I | Allen-Bradley ControlLogix 16-Point 240V AC Isolated Input Module1756-IM16I | Allen-Bradley ControlLogix 16-Point 240V AC Isolated Input Module1756-IM16I | Allen-Bradley ControlLogix 16-Point 240V AC Isolated Input Module
1756-IM16I | Allen-Bradley ControlLogix 16-Point 240V AC Isolated Input Module
1756-IM16I | Allen-Bradley ControlLogix 16-Point 240V AC Isolated Input Module
1756-IM16I | Allen-Bradley ControlLogix 16-Point 240V AC Isolated Input Module

1756-IM16I | Allen-Bradley ControlLogix 16-Point 240V AC Isolated Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-0B16I

PRODUCT TYPE : Digital AC Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IM16I is a high-performance 16-point isolated digital AC input module from the ControlLogix family. Each input channel is individually isolated to ensure superior noise immunity and reliable operation in demanding industrial environments. The module supports 240V AC nominal input signals at 50/60 Hz, making it ideal for interfacing with standard industrial control devices.

Technical Specifications

  • Model / Part Number: 1756-IM16I

  • Brand: Allen-Bradley

  • Product Line: ControlLogix

  • Product Type: Digital AC Input Module

  • Number of Inputs: 16 individually isolated channels

  • Voltage Category: 240V AC, 50/60 Hz

  • Operating Voltage Range: 159–265V AC, 47–63 Hz

  • Nominal Input Voltage: 240V AC, 50/60 Hz

  • Current Draw:

    • 5.1V DC: 100 mA

    • 24V DC: 3 mA

  • Backplane Power: 0.58 W

  • Power Dissipation (max): 5.8 W @ 60°C (140°F)

  • Thermal Dissipation: 19.78 BTU/hr

  • Input Delay Time:

    • Off → On: 10 ms hardware + 1 or 2 ms filter (selectable)

    • On → Off: 8 ms hardware + 9 or 18 ms filter (selectable)

  • Off-State Voltage (max): 40V AC

  • Off-State Current (max): 2.5 mA

  • On-State Current:

    • Minimum: 5 mA @ 159V AC, 60 Hz

    • Maximum: 13 mA @ 265V AC, 60 Hz

  • Input Impedance (max): 20.38 kΩ @ 265V AC, 60 Hz

  • Inrush Current (max): 250 mA

  • Isolation Voltage:

    • 250V AC continuous (basic insulation type)

    • Tested at 1350V AC for 2 seconds (input-to-backplane and input-to-input)

  • Cyclic Update Time: 200 μs to 750 ms (software configurable)

  • Change of State Detection: Software configurable

  • Timestamp Resolution: ±200 μs

  • Compatible Terminal Blocks: 1756-TBCH or 1756-TBS6H (removable)

  • RTB Keying: User-defined mechanical keying

  • Slot Width: 1

  • Enclosure Type: Open-style (for panel-mounted ControlLogix chassis)

  • Temperature Code:

    • North American: T4

    • IEC: T4

  • Operating Temperature: 0°C to 60°C (32°F to 140°F)

  • Vibration: 10–500 Hz, 2 g peak

Key Features

  • 16 fully isolated 240V AC input channels for maximum signal integrity

  • Configurable software filtering for improved noise rejection

  • Time-stamped input change detection for precision data logging

  • High isolation voltage for protection against transient surges

  • Compatible with standard ControlLogix chassis and removable terminal blocks

Applications

  • Power distribution and monitoring systems

  • Industrial automation and machine control

  • Input interfacing for AC sensors, switches, and actuators

  • Control panels requiring isolated input signals

FAQs

Q1: What makes the 1756-IM16I different from non-isolated input modules?
Each input channel on the 1756-IM16I is individually isolated, reducing ground noise and minimizing interference in sensitive automation systems.

Q2: What removable terminal blocks can be used with this module?
The 1756-IM16I is compatible with both 1756-TBCH and 1756-TBS6H removable terminal blocks.

Q3: How is the input filter configured?
Filter times (1/2 ms or 9/18 ms) are user-selectable via software, allowing optimization for fast or noise-prone environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more