1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM
1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM
1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM
1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM

1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM


Only 10 left - Selling fast

PRODUCT SKU : 1747-M11

PRODUCT TYPE : Memory Module Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1747-M11 is a memory module adapter designed for the SLC 500 series, providing 32KB of EEPROM memory to back up user programs for select SLC 500 processors. This module ensures reliable and fast memory backup for critical control processes. It is compatible with the SLC 5/03, 5/04, and 5/05 processors, offering flexible integration and high performance for industrial automation applications.

Key Features

 Memory Type: EEPROM
 User Memory: 32KB (64,000 words)
 Compatibility: Supports SLC 5/03, 5/04, and 5/05 processors
 Backup Memory: Flash EEPROM for reliable data storage
 Program Scan Time: 0.9 milliseconds for quick processing
 I/O Scan Time: 0.225 milliseconds for fast data communication
 Supported Processors: 1747-L532, 1747-L541, 1747-L542, 1747-L543
 Incompatible Modules: Does not support 1746-BAS or 1746-BAST
 Installation: Requires 1747-M15 adapter for PROM programmer installation

Technical Specifications

 Manufacturer: Rockwell Automation
 Brand: Allen-Bradley
 Part Number/Catalog No.: 1747-M11
 Series: SLC 500
 Module Type: Memory Module Adapter
 Memory Size: 32KB
 I/O Chassis: Supports up to 3 chassis
 Chassis Slots: Up to 30 slots
 Communication: Ethernet, RS-232
 Program Scan Time: 0.9 ms
 I/O Scan Time: 0.225 ms

Applications

The 1747-M11 is designed to back up control programs and data for a wide range of industrial automation systems, particularly those using Allen-Bradley SLC 500 processors. Typical applications include:
 Industrial Control Systems: Ensures program data retention during power outages
 Manufacturing Automation: Provides memory backup for assembly lines and machine control systems
 Process Control: Used for critical data backup in chemical, food processing, and pharmaceutical industries
 Building Management Systems: Stores and backs up data for HVAC and energy management systems

Advantages

 Reliable Data Backup: Flash EEPROM ensures that user programs are safely backed up and retrievable
 Fast Performance: Quick scan times (0.9 ms for programs, 0.225 ms for I/O) optimize overall system performance
 Ease of Integration: Compatible with various SLC 500 processors, offering flexibility in system configurations
 Cost-effective: A cost-efficient solution for extending memory capabilities without requiring a new controller

FAQ

Q1: Which processors are compatible with the 1747-M11?
A1: The 1747-M11 is compatible with SLC 5/03, SLC 5/04, and SLC 5/05 processors.

Q2: What is the memory size of the 1747-M11?
A2: The 1747-M11 offers 32KB of user memory (64,000 words), which is used to back up control programs.

Q3: Does the 1747-M11 require any special installation?
A3: Yes, the 1747-M11 requires the 1747-M15 adapter for installing a PROM programmer.

Q4: What is the scan time of the 1747-M11 module?
A4: The 1747-M11 has a program scan time of 0.9 ms and an I/O scan time of 0.225 ms, providing fast system performance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more