PRODUCT SKU : 1715-TADOB8DE

PRODUCT TYPE : Termination Assembly

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1715-TADOB8DE Termination Assembly is engineered for 8-channel digital output duplex configurations, offering reliable signal termination, fuse protection, and stable performance in distributed I/O systems. Its design ensures dependable operation in industrial automation environments where redundancy and precision are critical.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Number: 1715-TADOB8DE

  • Product Type: Termination Assembly, 8-Channel DO Duplex

  • Fuse Rating: 50 mA per channel

  • Screw Torque: 0.5 N·m (0.37 lb·ft)

  • Screwdriver Width: Flathead 0.4 × 2.0 mm (0.0156 × 0.0781 in.)

  • Backplane Current: 0.5 A per channel at 18–32 VDC

  • Field Voltage Slew Rate (Max): 150 V/s

  • De-energized Output Voltage Slew Rate (Max): 12 V/ms

  • Energized Output Current Slew Rate (Max): 0.9 A/ms

  • System Power Dissipation: 3.0 W maximum

  • Field Loop Power Dissipation: 0.17 W per loop maximum

  • Isolation Voltage: 50 V continuous, basic insulation type (I/O ports to backplane); no isolation between individual I/O ports; type tested at 500 V AC for 60 seconds

  • Dimensions (W × H): 8.4 cm × 13.2 cm

  • Weight: 0.26 kg

Application Scenarios

  • Digital Output Control: Provides reliable termination for duplex digital output signals

  • Distributed I/O Systems: Ensures stable performance in redundant configurations

  • Industrial Automation: Suitable for manufacturing, process control, and safety-critical environments

FAQ

  • Q: What type of fuse protection is included?  A: Each channel is protected with a 50 mA fuse, ensuring fault isolation and reliability.

  • Q: Does the assembly provide isolation between channels?  A: No, there is no isolation between individual I/O ports. However, the assembly provides 50 V continuous isolation between I/O ports and the backplane.

  • Q: What is the maximum system power dissipation?  A: The system power dissipation is 3.0 W maximum, with 0.17 W per field loop.

  • Q: How does this model compare to the 1715-TADIF16?  A: The 1715-TADOB8DE is designed for digital output duplex applications, while the 1715-TADIF16 is intended for analog input duplex configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Open Platform Communication (OPC): The Backbone of Industrial Interoperability

Demystifying Open Platform Communication (OPC): The Backbone of Industrial Interoperability

Interoperability remains a cornerstone requirement for modern smart factories and process automation. Open Platform Communication (OPC) bridges the gap between disparate hardware platforms, control systems, and visualization software. By establishing a universal communication standard, OPC allows field controllers, SCADA platforms, and enterprise software from different vendors to exchange real-time data seamlessly.

Read more
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more