Skip to content

What are you looking for?


You may also like

1715-TADOB8DE | Allen-Bradley | Termination Assembly | 8-Channel DO Duplex1715-TADOB8DE | Allen-Bradley | Termination Assembly | 8-Channel DO Duplex1715-TADOB8DE | Allen-Bradley | Termination Assembly | 8-Channel DO Duplex
1715-TADOB8DE | Allen-Bradley | Termination Assembly | 8-Channel DO Duplex
1715-TADOB8DE | Allen-Bradley | Termination Assembly | 8-Channel DO Duplex
1715-TADOB8DE | Allen-Bradley | Termination Assembly | 8-Channel DO Duplex

1715-TADOB8DE | Allen-Bradley | Termination Assembly | 8-Channel DO Duplex


Only 10 left - Selling fast

PRODUCT SKU : 1715-TADOB8DE

PRODUCT TYPE : Termination Assembly

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1715-TADOB8DE Termination Assembly is engineered for 8-channel digital output duplex configurations, offering reliable signal termination, fuse protection, and stable performance in distributed I/O systems. Its design ensures dependable operation in industrial automation environments where redundancy and precision are critical.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Number: 1715-TADOB8DE

  • Product Type: Termination Assembly, 8-Channel DO Duplex

  • Fuse Rating: 50 mA per channel

  • Screw Torque: 0.5 N·m (0.37 lb·ft)

  • Screwdriver Width: Flathead 0.4 × 2.0 mm (0.0156 × 0.0781 in.)

  • Backplane Current: 0.5 A per channel at 18–32 VDC

  • Field Voltage Slew Rate (Max): 150 V/s

  • De-energized Output Voltage Slew Rate (Max): 12 V/ms

  • Energized Output Current Slew Rate (Max): 0.9 A/ms

  • System Power Dissipation: 3.0 W maximum

  • Field Loop Power Dissipation: 0.17 W per loop maximum

  • Isolation Voltage: 50 V continuous, basic insulation type (I/O ports to backplane); no isolation between individual I/O ports; type tested at 500 V AC for 60 seconds

  • Dimensions (W × H): 8.4 cm × 13.2 cm

  • Weight: 0.26 kg

Application Scenarios

  • Digital Output Control: Provides reliable termination for duplex digital output signals

  • Distributed I/O Systems: Ensures stable performance in redundant configurations

  • Industrial Automation: Suitable for manufacturing, process control, and safety-critical environments

FAQ

  • Q: What type of fuse protection is included?  A: Each channel is protected with a 50 mA fuse, ensuring fault isolation and reliability.

  • Q: Does the assembly provide isolation between channels?  A: No, there is no isolation between individual I/O ports. However, the assembly provides 50 V continuous isolation between I/O ports and the backplane.

  • Q: What is the maximum system power dissipation?  A: The system power dissipation is 3.0 W maximum, with 0.17 W per field loop.

  • Q: How does this model compare to the 1715-TADIF16?  A: The 1715-TADOB8DE is designed for digital output duplex applications, while the 1715-TADIF16 is intended for analog input duplex configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding SCADA vs. HMI: A Technical Guide for Industrial Automation

Understanding SCADA vs. HMI: A Technical Guide for Industrial Automation

In the world of factory automation, professionals often use the terms HMI and SCADA interchangeably. However, these systems serve distinct roles within a control hierarchy. Understanding their unique functions is vital for designing efficient industrial automation architectures.

Read more
Microcontroller vs. PLC: Choosing the Right Controller for Industrial Automation

Microcontroller vs. PLC: Choosing the Right Controller for Industrial Automation

Engineers have long sought the perfect balance between flexibility and reliability when controlling complex systems. Today, two primary technologies dominate the landscape: the Microcontroller and the Programmable Logic Controller (PLC). While both serve as the "brain" of a system, they cater to vastly different environments. Understanding their core differences is essential for designing efficient control systems.

Read more
Essential DCS Commissioning Steps for Industrial Plant Success

Essential DCS Commissioning Steps for Industrial Plant Success

DCS commissioning is the vital bridge between construction and production. This phase validates that industrial automation infrastructure meets its functional design, ensuring safety and long-term reliability. By following rigorous protocols, engineers successfully transition from hardware installation to live process control.

Read more