Skip to content

What are you looking for?


You may also like

1440-TPS02-01RB | Allen-Bradley XM-320 Position Measurement Module1440-TPS02-01RB | Allen-Bradley XM-320 Position Measurement Module1440-TPS02-01RB | Allen-Bradley XM-320 Position Measurement Module
1440-TPS02-01RB | Allen-Bradley XM-320 Position Measurement Module
1440-TPS02-01RB | Allen-Bradley XM-320 Position Measurement Module
1440-TPS02-01RB | Allen-Bradley XM-320 Position Measurement Module

1440-TPS02-01RB | Allen-Bradley XM-320 Position Measurement Module


Only 10 left - Selling fast

PRODUCT SKU : 1440-TPS02-01RB

PRODUCT TYPE : Position Measurement Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley XM-320 (1440-TPS02-01RB) is a precision position module for turbine supervisory systems, capable of monitoring axial thrust, valve position, differential expansion, and case expansion. It features dual-channel inputs for eddy current transducers, LVDTs, or standard voltage sensors, with isolated 24V power and configurable software settings for sensitivity and voltage range. Outputs include two isolated 4–20 mA channels with buffered signal options. The module supports both DeviceNet and RS-232 communication, providing versatile integration into industrial control networks.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model Number: 1440-TPS02-01RB

  • Product Type: Position Measurement Module

  • Input Channels: 2

  • Signal Types: Eddy current, LVDT, voltage inputs from position sensors

  • Transducer Power: Isolated 24V, configurable for ±24V

  • Input Impedance: >100 kΩ

  • 4–20 mA Outputs: 2 isolated, max load 600 Ω, buffered

  • Indicators: Module status, network status, channel status, setpoint multiplier, relay status

  • Communication: DeviceNet (125/250/500 Kbps), RS-232 (19.2 Kbps), EDS support

  • Measurement Modes: Normal, Head-to-Head, Radial Cancel, Delta Time Buffer

  • Number of Records: 2048

  • Trigger Modes: Relay activation or DeviceNet command

  • Alarms: Two alarm/danger pairs with configurable operators and hysteresis

  • Relays: 1 onboard DPDT relay, optional XM-441 expansion relays, virtual relays supported

  • Relay Ratings: Max 125V DC/AC, 3.5A (derated to 2A at 65°C), max power 60W DC / 62.5 VA AC

  • Failsafe Options: Normally energized or de-energized, latching/non-latching, adjustable time delay 0–25.5 s

  • Configuration: Non-volatile, editable via DeviceNet or serial interface

  • Module Power: 24V DC, typical 165 mA, max 200 mA

  • Heat Production: Typical 3.96 W, max 5.28 W

  • Physical Dimensions: 97 × 94 × 94 mm (3.8 × 3.7 × 3.7 in)

  • Terminal Base: 1440-TB-B

Key Features

  • Dual-channel inputs with configurable sensitivity and signal type

  • Supports eddy current transducers, LVDTs, and standard voltage sensors

  • Flexible communication via DeviceNet or RS-232

  • Multiple relay options with failsafe and latching modes

  • Non-volatile configuration preserves settings across power cycles

Application Scenarios

  • Turbine supervisory position monitoring

  • Valve and thrust position measurement in industrial machinery

  • Integration into DeviceNet-based process control systems

  • Expansion with additional relay modules for complex alarm logic

FAQ

Q1: How many channels can the XM-320 monitor?
It supports two independent measurement channels.

Q2: Can this module work with standard voltage sensors?
Yes, it accepts voltage inputs from any compatible position measurement device.

Q3: What communication protocols are supported?
DeviceNet and RS-232, with automatic DeviceNet baud rate selection and EDS file support.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more