The Allen-Bradley XM-320 (1440-TPS02-01RB) is a precision position module for turbine supervisory systems, capable of monitoring axial thrust, valve position, differential expansion, and case expansion. It features dual-channel inputs for eddy current transducers, LVDTs, or standard voltage sensors, with isolated 24V power and configurable software settings for sensitivity and voltage range. Outputs include two isolated 4–20 mA channels with buffered signal options. The module supports both DeviceNet and RS-232 communication, providing versatile integration into industrial control networks.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model Number: 1440-TPS02-01RB

  • Product Type: Position Measurement Module

  • Input Channels: 2

  • Signal Types: Eddy current, LVDT, voltage inputs from position sensors

  • Transducer Power: Isolated 24V, configurable for ±24V

  • Input Impedance: >100 kΩ

  • 4–20 mA Outputs: 2 isolated, max load 600 Ω, buffered

  • Indicators: Module status, network status, channel status, setpoint multiplier, relay status

  • Communication: DeviceNet (125/250/500 Kbps), RS-232 (19.2 Kbps), EDS support

  • Measurement Modes: Normal, Head-to-Head, Radial Cancel, Delta Time Buffer

  • Number of Records: 2048

  • Trigger Modes: Relay activation or DeviceNet command

  • Alarms: Two alarm/danger pairs with configurable operators and hysteresis

  • Relays: 1 onboard DPDT relay, optional XM-441 expansion relays, virtual relays supported

  • Relay Ratings: Max 125V DC/AC, 3.5A (derated to 2A at 65°C), max power 60W DC / 62.5 VA AC

  • Failsafe Options: Normally energized or de-energized, latching/non-latching, adjustable time delay 0–25.5 s

  • Configuration: Non-volatile, editable via DeviceNet or serial interface

  • Module Power: 24V DC, typical 165 mA, max 200 mA

  • Heat Production: Typical 3.96 W, max 5.28 W

  • Physical Dimensions: 97 × 94 × 94 mm (3.8 × 3.7 × 3.7 in)

  • Terminal Base: 1440-TB-B

Key Features

  • Dual-channel inputs with configurable sensitivity and signal type

  • Supports eddy current transducers, LVDTs, and standard voltage sensors

  • Flexible communication via DeviceNet or RS-232

  • Multiple relay options with failsafe and latching modes

  • Non-volatile configuration preserves settings across power cycles

Application Scenarios

  • Turbine supervisory position monitoring

  • Valve and thrust position measurement in industrial machinery

  • Integration into DeviceNet-based process control systems

  • Expansion with additional relay modules for complex alarm logic

FAQ

Q1: How many channels can the XM-320 monitor?
It supports two independent measurement channels.

Q2: Can this module work with standard voltage sensors?
Yes, it accepts voltage inputs from any compatible position measurement device.

Q3: What communication protocols are supported?
DeviceNet and RS-232, with automatic DeviceNet baud rate selection and EDS file support.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more