Skip to content

What are you looking for?


You may also like

1426-M5E | Allen-Bradley Ser B PowerMonitor 5000 Basic Module1426-M5E | Allen-Bradley Ser B PowerMonitor 5000 Basic Module1426-M5E | Allen-Bradley Ser B PowerMonitor 5000 Basic Module
1426-M5E | Allen-Bradley Ser B PowerMonitor 5000 Basic Module
1426-M5E | Allen-Bradley Ser B PowerMonitor 5000 Basic Module
1426-M5E | Allen-Bradley Ser B PowerMonitor 5000 Basic Module

1426-M5E | Allen-Bradley Ser B PowerMonitor 5000 Basic Module


Only 10 left - Selling fast

PRODUCT SKU : 1426-M5E

PRODUCT TYPE : Power Monitoring Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1426-M5E Ser B is a compact PowerMonitor 5000 module designed for precise electrical parameter monitoring in industrial environments. It provides real-time measurement of current, voltage, frequency, and power metrics, supporting energy management and system diagnostics.

Technical Specifications

  • Model / Part Number: 1426-M5E Ser B

  • Brand: Allen-Bradley

  • Product Type: Power Monitoring Module

  • Product Line: PowerMonitor 5000

  • Weight: 3.00 lbs (1.36 kg)

  • Measurement Parameters: Current (A), Frequency (Hz), Voltage (V), Active Power (kW), Apparent Power (kVA), Reactive Power (kVAR), Energy (kWh, kVAh)

  • Sampling & Refresh Rate: One update per line cycle; 1024 samples per cycle per channel

  • Input Frequency (Nominal): 50 / 60 Hz

  • Input Frequency Range: 40–75 Hz

  • Input Current Range: 0.05–15.6 A

  • Maximum Single-Phase Current: 15.6 A RMS

  • Communication Protocols: EtherNet/IP

Application Scenarios

  • Monitoring electrical loads in industrial automation panels

  • Energy auditing and performance tracking for manufacturing facilities

  • Integration with Allen-Bradley PLCs and control systems for system diagnostics

Comparison with Similar Modules

  • Compared to 1426-M5E Ser A, the Ser B features improved sampling resolution and enhanced Ethernet connectivity.

  • Compatible with PowerMonitor 5000 series accessories and monitoring software.

FAQs

Q1: Can this module handle three-phase systems?
Yes, the module supports multi-phase monitoring when used with proper transformers or accessory modules.

Q2: What is the maximum operating frequency?
Up to 75 Hz, suitable for industrial power systems worldwide.

Q3: Which communication protocol is supported?
EtherNet/IP for integration with Allen-Bradley PLCs and HMI systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more