Product Description

The Honeywell 10311/2/1 Control/Reset Module is a dual key switch unit designed for Honeywell Fail Safe Controller (FSC) systems. It provides manual intervention for critical safety functions, including watchdog reset and force enable operations. With dual-key operation, the module ensures deliberate and secure activation of safety-critical commands, reducing the risk of accidental engagement.

Key Features

  • Model Number: 10311/2/1

  • Function: Dual key switch for reset and force enable operations

  • Current Consumption: 5 mA at 24 VDC (typical)

  • Maximum Voltage: 36 VDC

  • Maximum Current: 2 A

  • Reverse Polarity Protection: Integrated for safe operation

  • Space Requirement: 4 TE, 3 HE (≈ 4 HP, 3U)

  • Module Code: A5, A13

  • Rack Code: A5, A13

  • Dimensions: 120 × 100 × 50 mm

  • Weight: 0.118 kg

  • Country of Origin: USA

Application Scenarios

  • Safety-Critical Systems: Manual reset and force enable functions for FSC controllers in petrochemical, energy, and manufacturing plants

  • Redundant Architectures: Provides secure manual intervention in distributed control environments

  • Industrial Connectivity: Designed for integration into FSC racks with defined space requirements

  • Controlled Access: Dual key operation ensures deliberate and authorized activation of safety functions

FAQ

Q: What is the primary function of the 10311/2/1 module?  A: It provides dual key switch control for watchdog reset and force enable operations.

Q: What is the maximum current supported?  A: The module supports up to 2 A.

Q: Does the module include polarity protection?  A: Yes, reverse polarity protection is integrated.

Q: How does it compare to the Honeywell 10004/1/1 communication module?  A: The 10311/2/1 is designed for manual safety control functions, while the 10004/1/1 focuses on redundant communication between FSC controllers and distributed systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more