TC810 3BSE076220R1 ABB Communication ModuleTC810 3BSE076220R1 ABB Communication ModuleTC810 3BSE076220R1 ABB Communication Module
TC810 3BSE076220R1 ABB Communication Module
TC810 3BSE076220R1 ABB Communication Module
TC810 3BSE076220R1 ABB Communication Module

TC810 3BSE076220R1 ABB Communication Module


Only 10 left - Selling fast

PRODUCT SKU : TC810 3BSE076220R1

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BSE076220R1, also cataloged as the TC810 Communication Module, operates as a dedicated hardware component for isolated variable loop command control within ABB automation systems.

Hardware Specifications

Parameter Specification
Model TC810 (Product ID: 3BSE076220R1)
Brand ABB
Origin Sweden
Weight 0.102 kg
Dimensions 24.5 mm x 110 mm x 77 mm
Operating Temp 0 to +55 deg C (Standard industrial parameters)
Power Consumption Internally derived via backplane interface assembly
Product Type Communication Modules
Interface Media Copper media
Port Configuration 2 x RJ45 ports (Built-in 2-port switch)
Redundancy Architecture Supports single or redundant configuration topologies
RoHS Status Following EU Directive 2011/65/EU
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)

Profinet / EtherNet/IP Deterministic Networks and Switching Logic

The internal switching architecture of the TC810 coordinates dual-channel packet routing over copper media interfaces directly from the Field Communication Interface (FCI) platform. This hardware configuration maintains continuous data throughput matching synchronous control loop vectors, directly protecting host backplane bus communication velocity metrics during active register polling cycles. By handling local switching logic through integrated hardware, the module coordinates runtime operations seamlessly across adjacent Profinet / EtherNet/IP deterministic networks. The module preserves full firmware flash compatibility with upstream automation controllers, ensuring that multi-drop topological extensions do not compromise I/O density scaling options across the physical bus layout.

Frequently Asked Questions

Q: Does the TC810 communication adapter support hot-swap extraction under active data processing conditions?

A: Online removal is supported exclusively when the unit is configured in a redundant architecture layout. If deployed as a single, non-redundant interface, extraction will break the network loop, immediately dropping active register polling and generating communications fault diagnostics on the controller.

Q: How is the physical network redundancy handled within the integrated 2-port switch logic?

A: The dual RJ45 ports link directly to redundant media streams, shifting internal register assignments dynamically upon port-link failure detection. This switching loop operates at the hardware layer, ensuring transition delays conform to standard industrial deterministic interface profiles.

Q: Are specialized software keys needed to synchronize firmware flash compatibility during unit replacement?

A: No. The adapter synchronizes its operational profiles based on hardware identification markers and the software parameters defined by the master FCI node. Verification of the physical address selection switches must occur before inserting the card into the chassis slot.

Field Installation Guidelines

  • Chassis Insertion and Retention: Secure the 24.5 mm housing onto the designated backplane terminal base slot. Push orthogonally until the locking clips click into position to neutralize mechanical strain from structural industrial vibrations.
  • Shielded Network Cable Specification: Utilize Category 5e or better shielded twisted-pair (STP) lines for the copper media links. Terminate the metal connector shrouds to common chassis earth ground to prevent field noise from altering packet propagation.
  • Port Bending Constraints: Route the RJ45 copper communication cables out of the 77 mm depth plane via dedicated plastic wiring paths. Maintain a baseline minimum bend radius of 25 mm to protect the wire jackets from crimping.
  • Thermal Boundary Spacing: Confirm that neighboring components do not impede convective airflow paths surrounding the module case. Ambient temperatures inside the termination cabinet must not surpass the standard +55 deg C operating limit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.