Only 10 left - Selling fast

PRODUCT SKU : 9905-971

PRODUCT TYPE : Discrete Input Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed state monitoring in turbine control platforms, the Woodward 9905-971 (9905-971 Discrete Input Module) provides direct physical/electrical execution of 24 VDC contact signal acquisition.

Suffix Breakdown & Model Matrix

The 9905-971 operates as a standardized discrete input interface within the Woodward control chassis. This model is categorized as a 24-channel discrete input module featuring an update time of 5 ms and a time-stamping resolution of 1 ms. No alternate hardware revisions or functional sub-variants are defined for this specific catalog number; the unit is configured as a singular hardware assembly for integration into chassis card guides.

Hardware Specifications

Parameter Specification
Model 9905-971
Brand Woodward
Origin USA
Power Consumption 24 VDC
Input Channels 24
Update Time 5 ms
Time Stamping 1 ms resolution

V/Hz and Field-Oriented Vector Control

The 9905-971 provides the critical status feedback necessary for the execution of V/Hz and field-oriented vector control algorithms. By capturing discrete state changes with a 1 ms resolution, the module ensures that the governing system maintains precise synchronization with external turbine valve feedback and auxiliary contact positions. The integration of latent fault detection within the discrete input logic permits the monitoring system to distinguish between intended contact states and hardware-level malfunctions, thereby maintaining the integrity of the control loop feedback response during dynamic operational transients.

Frequently Asked Questions

Q: Are the discrete input channels galvanically isolated?

A: Yes, all discrete inputs are fully isolated. A common reference point must be established between the inputs and the external contact power source to ensure proper signal referencing.

Q: What are the requirements for using the internal vs. external power source for contact wetting?

A: If the internal 24 VDC power source is used, jumpers must be installed between module terminals 33, 34, and 35. When utilizing an external power source (18-32 VDC or 100-150 VDC), the common of the external source must be connected to terminals 34 and 35.

Field Installation Guidelines

  1. Chassis Insertion: Align the module with the chassis card guides. Slide the module in until the edge connector makes full contact with the motherboard.
  2. Mechanical Security: Secure the front panel to the chassis using the top and bottom mounting screws to prevent vibration-induced disconnection.
  3. Common Referencing: Ensure the discrete input common (terminals 34 and 35) is appropriately referenced to the contact wetting power source to prevent floating input signals.
  4. Wiring Termination: Verify all field wiring connections for tightness. For 24 VDC contact wetting, ensure required terminal jumpers are installed to bridge the internal supply.
  5. Extraction: To remove, toggle the top and bottom handles outward to disengage the board from the motherboard connectors before sliding the module out of the chassis.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more