Skip to content

What are you looking for?


You may also like

UR Series | GE Fanuc Multilin UR 8LV/UR8LV | CT/VT Measurement ModuleUR Series | GE Fanuc Multilin UR 8LV/UR8LV | CT/VT Measurement ModuleUR Series | GE Fanuc Multilin UR 8LV/UR8LV | CT/VT Measurement Module
UR Series | GE Fanuc Multilin UR 8LV/UR8LV | CT/VT Measurement Module
UR Series | GE Fanuc Multilin UR 8LV/UR8LV | CT/VT Measurement Module
UR Series | GE Fanuc Multilin UR 8LV/UR8LV | CT/VT Measurement Module

UR Series | GE Fanuc Multilin UR 8LV/UR8LV | CT/VT Measurement Module


Only 10 left - Selling fast

PRODUCT SKU : UR8LV

PRODUCT TYPE : CT/VT Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  The GE UR8LV CT/VT Module is a precision measurement unit within the Fanuc Multilin Universal Relay (UR) series. It is designed to capture accurate current and voltage data, ensuring reliable monitoring and protection in power system applications. With its robust construction and DIN rail mounting capability, the UR8LV is suitable for demanding industrial environments.

Technical Specifications

  • Manufacturer: General Electric Fanuc Multilin

  • Model: UR8LV

  • Type: CT/VT Module

  • Input Voltage Range: 120 V AC to 480 V AC

  • Input Current Range: 1 A to 5 A

  • Burden Rating: 1 VA

  • Frequency Range: 50/60 Hz

  • Operating Temperature: -40°C to +70°C (-40°F to +158°F)

  • Storage Temperature: -40°C to +85°C (-40°F to +185°F)

  • Dimensions: 180 mm × 100 mm × 40 mm

  • Weight: 1.0 kg

  • Mounting Type: DIN rail mountable

Key Features

  • High-performance CT/VT measurement for accurate system monitoring

  • Wide input voltage and current ranges for flexible application

  • Compact DIN rail mountable design for simplified installation

  • Rugged construction for reliable operation in harsh environments

Applications

  • Power generation and distribution monitoring

  • Substation automation requiring CT/VT measurement

  • Industrial process control systems

  • Relay-based protection schemes in mission-critical environments

FAQ

  • Q: What voltage range does the UR8LV support?  A: It supports input voltages from 120 V AC to 480 V AC.

  • Q: What current range can the UR8LV measure?  A: It measures currents between 1 A and 5 A.

  • Q: How is the UR8LV installed?  A: It is DIN rail mountable for easy integration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more