Skip to content

What are you looking for?


You may also like

UR 77H/UR7CH GE Multilin Fiber-Optic Inter-Relay Communications ModuleUR 77H/UR7CH GE Multilin Fiber-Optic Inter-Relay Communications ModuleUR 77H/UR7CH GE Multilin Fiber-Optic Inter-Relay Communications Module
UR 77H/UR7CH GE Multilin Fiber-Optic Inter-Relay Communications Module
UR 77H/UR7CH GE Multilin Fiber-Optic Inter-Relay Communications Module
UR 77H/UR7CH GE Multilin Fiber-Optic Inter-Relay Communications Module

UR 77H/UR7CH GE Multilin Fiber-Optic Inter-Relay Communications Module


Only 10 left - Selling fast

PRODUCT SKU : UR7CH

PRODUCT TYPE : Communications Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  

The GE UR77H Inter-Relay Communications Module, part of the Multilin Universal Relay (UR) series, is engineered to enable high-speed fiber-optic communication between UR relays. It supports teleprotection, fast tripping, and coordinated control, ensuring secure and reliable data exchange in modern power system protection schemes.

Technical Specifications

  • Manufacturer: General Electric (GE)

  • Model: UR77H

  • Type: Inter-Relay Communications Module

  • Function: Relay-to-relay communications

  • Communication Standard: IEEE C37.94

  • Transmission Medium: Multimode fiber optic

  • Wavelength: 820 nm

  • Number of Channels: 2

  • Indicators: LED status indicators for diagnostics

  • Mounting Orientation: Horizontal installation within UR chassis

  • Dimensions: 280 mm × 115 mm × 45 mm

  • Weight: 0.6 kg

  • Country of Origin: USA

Key Features

  • Enables exchange of digital status and analog values between UR relays

  • Supports fast tripping and teleprotection applications

  • Noise-immune fiber-optic communication for reliable performance

  • Compact modular design for seamless integration into UR systems

  • Built for demanding industrial and utility environments

Applications

  • Substation automation requiring relay-to-relay communication

  • Power system protection and coordination

  • Teleprotection schemes for transmission lines

  • Industrial control systems with distributed relay networks

FAQ

  • Q: What communication standard does the UR77H support?  A: It complies with IEEE C37.94 for inter-relay communication.

  • Q: How many channels are available?  A: The UR77H provides 2 fiber-optic channels.

  • Q: What wavelength does the module operate at?  A: It uses 820 nm multimode fiber optic transmission.

  • Q: Is the UR77H suitable for teleprotection?  A: Yes, it is specifically designed for fast tripping and teleprotection applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more