Skip to content

What are you looking for?


You may also like

Schneider NF301NNS7SD5 NF300 Series Molded Case Circuit Breaker 30A 3PSchneider NF301NNS7SD5 NF300 Series Molded Case Circuit Breaker 30A 3PSchneider NF301NNS7SD5 NF300 Series Molded Case Circuit Breaker 30A 3P
Schneider NF301NNS7SD5 NF300 Series Molded Case Circuit Breaker 30A 3P
Schneider NF301NNS7SD5 NF300 Series Molded Case Circuit Breaker 30A 3P
Schneider NF301NNS7SD5 NF300 Series Molded Case Circuit Breaker 30A 3P

Schneider NF301NNS7SD5 NF300 Series Molded Case Circuit Breaker 30A 3P


Only 10 left - Selling fast

PRODUCT SKU : NF301NNS7SD5

PRODUCT TYPE : Circuit Breaker

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Schneider NF301NNS7SD5 is a three-pole molded case circuit breaker (MCCB) designed for dependable protection in industrial and commercial electrical systems. It delivers precise overload and short-circuit protection, ensuring efficient power distribution and equipment safety.

As part of the NF300 Series, this breaker supports a rated current of 30A and a breaking capacity of 50kA at 480V AC. Its compact design allows easy installation in control panels or switchboards using either DIN rail or panel mounting.

Built in compliance with IEC/EN 60947-2, the NF301NNS7SD5 meets international safety standards and provides long-term reliability in demanding environments.

Key Features

  • Model Number: NF301NNS7SD5

  • Manufacturer: Schneider Electric

  • Series: NF300

  • Type: Molded Case Circuit Breaker (MCCB)

  • Rated Current: 30A

  • Poles: 3P (Three-pole)

  • Rated Voltage: 480V AC

  • Breaking Capacity: 50kA at 480V AC

  • Mounting Type: DIN rail or panel-mounted

  • Operating Temperature: -25°C to +70°C

  • Dimensions: 110 × 80 × 75 mm

  • Weight: 1.2 kg

  • Compliance Standards: IEC/EN 60947-2

Applications

The NF301NNS7SD5 is suitable for various applications requiring reliable electrical circuit protection, including:

  • Industrial automation and machinery systems

  • Commercial building power distribution

  • Utility and energy management systems

  • Renewable energy and inverter systems

  • Control panels and electrical switchboards

Its compact size, high breaking capacity, and durable design make it ideal for both new installations and system upgrades.

FAQ

Q1: Is the NF301NNS7SD5 an original Schneider product?
A1: Yes, it is an authentic product manufactured by Schneider Electric.

Q2: What is the breaking capacity of this MCCB?
A2: It has a breaking capacity of 50kA at 480V AC.

Q3: How can this circuit breaker be mounted?
A3: It supports both DIN rail and panel mounting options.

Q4: What standards does it meet?
A4: It conforms to IEC/EN 60947-2 international safety standards.

Q5: What environments can it operate in?
A5: It can operate reliably within a temperature range of -25°C to +70°C.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more