Skip to content

What are you looking for?


You may also like

ProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Communication ModuleProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Communication ModuleProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Communication Module
ProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Communication Module
ProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Communication Module
ProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Communication Module

ProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Communication Module


Only 10 left - Selling fast

PRODUCT SKU : MVI56-PDPMV1

PRODUCT TYPE : Master Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MVI56-PDPMV1 module from ProSoft Technology is a PROFIBUS DP-V1 Master interface designed for Allen Bradley ControlLogix systems. This single-slot communication module enables high-speed PROFIBUS DP-V1 connectivity, providing engineers with a reliable solution for integrating ControlLogix controllers into PROFIBUS networks. Although discontinued by the manufacturer, it remains a reference point for legacy system support.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Product Line: ControlLogix

  • Model: MVI56-PDPMV1

  • Part Number: MVI56-PDPMV1

  • Product Type: PROFIBUS DP-V1 Master Network Interface Module

  • Weight: 1.50 lbs (approx. 0.68 kg)

  • Slot(s): Single slot

  • Rack Type: Local or Remote

  • Power Supply: 24 VDC

  • Baud Rate: Up to 12 Mbps (12000 kbit/s)

  • Interface Port: RS-232

  • Operating Temperature: 0 to +60 °C

  • Data Transfer Type: Ladder Logic

Core Features

  • PROFIBUS DP-V1 Master functionality for ControlLogix systems

  • High-speed communication up to 12 Mbps

  • RS-232 port for configuration and diagnostics

  • Compact single-slot design for flexible installation

  • Industrial-grade reliability with wide operating temperature range

Application Scenarios

  • Integration of PROFIBUS DP-V1 field devices into ControlLogix controllers

  • Distributed control systems requiring PROFIBUS master communication

  • Legacy automation environments needing stable PROFIBUS connectivity

FAQ

  • Q: Is the MVI56-PDPMV1 still in production?  A: No, it has been discontinued by ProSoft Technology.

  • Q: What is the maximum baud rate supported?  A: The module supports communication speeds up to 12 Mbps.

  • Q: Can this module be used in remote racks?  A: Yes, it supports both local and remote rack configurations.

Comparison with Similar Modules

  • MVI56-PDPS: PROFIBUS DP Slave interface, designed for slave device integration.

  • MVI56-MCM: Modbus communication module, suitable for Modbus networks.

  • MVI56-EIP: EtherNet/IP communication module, ideal for Ethernet-based systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more