Skip to content

What are you looking for?


You may also like

MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HARTMU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HARTMU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART
MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART
MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART
MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART

MU/MC-TAIH12 51304337-100 | Honeywell | Smart Transmitter Interface | HART


Only 10 left - Selling fast

PRODUCT SKU : MU/MC-TAIH12 51304337-100

PRODUCT TYPE : Smart Transmitter Interface

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell MU/MC-TAIH12 (51304337-100) Smart Transmitter Interface is designed to integrate intelligent field transmitters into industrial automation systems. Supporting HART communication, it enables seamless digital data exchange while maintaining analog signal compatibility. With fast response times and robust design, this interface ensures reliable performance in demanding environments.

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: MU/MC-TAIH12

  • Order/Part Number: 51304337-100

  • Product Type: Smart Transmitter Interface

  • Power Supply: 24 VDC

  • Operating Temperature: –40 °C to +85 °C

  • Communication Protocol: HART

  • Input Impedance: 250 Ω

  • Response Time: <1 second

Application Scenarios

  • Integration of HART-enabled smart transmitters in distributed control systems (DCS)

  • Oil & gas process monitoring and control

  • Chemical processing plants requiring precise transmitter communication

  • Power generation and manufacturing automation systems

FAQ

Q: What is the advantage of HART communication in MU/MC-TAIH12?  
A: HART allows digital communication over existing analog wiring, enabling advanced diagnostics and configuration without additional infrastructure.

Q: Can this interface be used with non-HART transmitters?  
A: Yes, it supports analog signals, but full functionality is achieved with HART-enabled devices.

Q: How fast is the response time?  
A: The module responds in less than one second, ensuring timely data acquisition for process control.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more