Skip to content

What are you looking for?


You may also like

Modicon Quantum | Schneider Electric 140ACI04000 16-Channel Analog Input ModuleModicon Quantum | Schneider Electric 140ACI04000 16-Channel Analog Input ModuleModicon Quantum | Schneider Electric 140ACI04000 16-Channel Analog Input Module
Modicon Quantum | Schneider Electric 140ACI04000 16-Channel Analog Input Module
Modicon Quantum | Schneider Electric 140ACI04000 16-Channel Analog Input Module
Modicon Quantum | Schneider Electric 140ACI04000 16-Channel Analog Input Module

Modicon Quantum | Schneider Electric 140ACI04000 16-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 140ACI04000

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 140ACI04000 is a high-precision 16-channel analog input module designed for the Modicon Quantum automation platform. It provides accurate current measurement with excellent linearity and stability, supporting differential inputs for robust signal acquisition.

Technical Specifications

  • Model + Part Number: 140ACI04000

  • Manufacturer: Schneider Electric

  • Product Line: Modicon Quantum

  • Product Type: Analog Input Module

  • Analog Input Channels: 16

  • Input Type: Differential

  • Input Range: 0…25 mA, 0…20 mA, 4…20 mA

  • Input Resolution:

    • 0…16000 counts for 4…20 mA

    • 0…20000 counts for 0…20 mA

    • 0…25000 counts for 0…25 mA

    • 0…4095 counts for 4…20 mA (alternative)

  • Absolute Maximum Input: 30 mA

  • Input Impedance: 250 Ω

  • Absolute Accuracy: ±0.125% of full scale

  • Linearity Error:

    • ±12 μA for 4…20 mA

    • ±6 μA for 0…20 mA

    • ±6 μA for 0…25 mA

  • Temperature Drift: ±0.0025% of full scale/°C

  • Common Mode Rejection: >90 dB at 60 Hz

  • Isolation Between Channels and Bus: 1780 V AC for 60 s

  • Update Time: 15 ms for 2- and 4-wire inputs

  • Fault Detection: Broken wire detection for 4…20 mA circuits

  • Local Signalling:

    • 1 green LED for bus activity

    • 1 red LED for external fault

    • 16 green LEDs for channel active

    • 16 red LEDs for channel fault

  • Bus Current Requirement: 360 mA

  • Power Dissipation: 5 W

  • Module Format: Standard

  • Net Weight: 0.66 lb (0.3 kg)

Applications
Suitable for monitoring multiple analog current signals in process control systems, the 140ACI04000 ensures accurate data acquisition for Modicon Quantum controllers in manufacturing and process industries.

FAQ
Q: What is the maximum input current supported?
A: The module can handle up to 30 mA absolute maximum input.
Q: How is fault detection implemented?
A: It detects broken wires on 4…20 mA input circuits.
Q: What update rate does it provide for input channels?
A: The update time is 15 ms for 2-wire and 4-wire configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more