PRODUCT SKU : IC200UDR164

PRODUCT TYPE : Micro PLC

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax Micro IC200UDR164 PLC is a compact and versatile controller engineered for demanding industrial automation tasks. With 64 total I/O points, integrated power supply, and flexible communication options, it delivers reliable performance in environments requiring real-time control and expandability.

Technical Specifications

  • Model / Part Number IC200UDR164

  • Manufacturer GE Fanuc Emerson

  • Product Line VersaMax Micro

  • Product Type Programmable Logic Controller (PLC)

  • Weight 0.94 lbs (0.43 kg)

  • Total I/O Points 64

  • Digital Inputs 40 points, 24 VDC

  • Relay Outputs 24 points, Form C/SPDT, supports AC/DC loads

  • Power Supply Integrated 115/240 VAC input

  • Communication Ports

    • 1 standard serial port

    • 1 optional port for Ethernet or serial expansion

  • Memory Expandable user memory with plug-in modules

  • Programming Software Proficy Machine Edition

  • Scan Rate Fast response for real-time control applications

  • Operating Temperature Range –40°C to +70°C

  • Storage Temperature Range –40°C to +85°C

  • Humidity 5% to 95% non-condensing

Application Scenarios

  • Mid-size automation systems requiring mixed AC/DC relay outputs

  • Distributed control networks needing Ethernet or RS-485 expansion

  • Harsh industrial environments requiring wide operating temperature ranges

FAQ

Q: How many I/O points does the IC200UDR164 support?  A: It provides 64 total points (40 inputs and 24 relay outputs).

Q: Does the PLC include an integrated power supply?  A: Yes, it supports 115/240 VAC input directly.

Q: Can memory be expanded?  A: Yes, user memory can be expanded with plug-in modules for program updates.

Q: What programming software is required?  A: Proficy Machine Edition is used for configuration and programming.

Comparison with Similar Models

  • IC200UDR005: 28-point Micro PLC, expandable to 140 points, dual communication ports

  • IC200UDR164: 64-point Micro PLC, integrated power supply, relay outputs for AC/DC loads

  • IC200UAA003: Entry-level Micro PLC with fewer I/O points, suited for small applications

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more