Skip to content

What are you looking for?


You may also like

Honeywell XLS3000-CPUD Fire Alarm Control Panel CPU Display ModuleHoneywell XLS3000-CPUD Fire Alarm Control Panel CPU Display ModuleHoneywell XLS3000-CPUD Fire Alarm Control Panel CPU Display Module
Honeywell XLS3000-CPUD Fire Alarm Control Panel CPU Display Module
Honeywell XLS3000-CPUD Fire Alarm Control Panel CPU Display Module
Honeywell XLS3000-CPUD Fire Alarm Control Panel CPU Display Module

Honeywell XLS3000-CPUD Fire Alarm Control Panel CPU Display Module


Only 10 left - Selling fast

PRODUCT SKU : XLS3000-CPUD

PRODUCT TYPE : Fire Alarm Control Panels

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell XLS3000-CPUD, also cataloged as the XLS3000-CPUD CPU Display Module, operates as a dedicated hardware component for central signal processing and network display management within XLS3000 fire alarm control panel platforms.

Hardware Specifications

Parameter Specification
Model XLS3000-CPUD
Brand Honeywell
Origin USA
Weight 2.91 lbs
Dimensions Standard chassis assembly footprint
Operating Temp 0 to +49 deg C
Power Consumption Current consumption 0.12 A
System Type Intelligent Addressable Fire Alarm Control Panel CPU
Signaling Line Circuits 1 to 10 isolated intelligent SLCs
Device Capacity Up to 3,180 intelligent addressable devices
Display Type 16-line, 640-character backlit LCD display
Network Protocol Peer-to-peer device communication
Standards Compliance UL 2572 Mass Notification, Seismic certified (with kit)

Channel-to-Channel Isolation and Loop Network Protocols

The CPU module incorporates galvanic channel-to-channel isolation across all 1 to 10 Signaling Line Circuit (SLC) interface ports. Optical isolation stages protect internal processor buses against external field wiring ground faults and surge transients. Peer-to-peer communication protocols maintain deterministic frame synchronization across the SLC loops, ensuring sub-second response times for alarm initiation and output activation across all connected 3,180 addressable field points.

Frequently Asked Questions

Q: How many addressable field devices can be managed by the XLS3000-CPUD processor?

A: The module supports up to 10 isolated Signaling Line Circuits (SLCs), providing system capacity for up to 3,180 intelligent addressable devices.

Q: What power draw does the XLS3000-CPUD CPU require from the panel supply?

A: The central processor display assembly draws a nominal operating current of 0.12 A from the system power supply board.

Field Installation Guidelines

  1. Ensure panel primary AC supply and secondary battery power are disconnected before mounting the CPU module into the chassis backbox.
  2. Align the CPU board mounting holes with the chassis standoffs and secure using grounding screws to establish earth ground continuity.
  3. Route SLC field wiring in separate conduit pathways from AC power lines to avoid inductive electrical noise.
  4. Connect all SLC circuit shield wires to designated cabinet earth ground points according to system wiring diagrams.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Open Platform Communication (OPC): The Backbone of Industrial Interoperability

Demystifying Open Platform Communication (OPC): The Backbone of Industrial Interoperability

Interoperability remains a cornerstone requirement for modern smart factories and process automation. Open Platform Communication (OPC) bridges the gap between disparate hardware platforms, control systems, and visualization software. By establishing a universal communication standard, OPC allows field controllers, SCADA platforms, and enterprise software from different vendors to exchange real-time data seamlessly.

Read more
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.