Skip to content

What are you looking for?


You may also like

Honeywell 51155506-100 Isolated Analog Output ModuleHoneywell 51155506-100 Isolated Analog Output ModuleHoneywell 51155506-100 Isolated Analog Output Module
Honeywell 51155506-100 Isolated Analog Output Module
Honeywell 51155506-100 Isolated Analog Output Module
Honeywell 51155506-100 Isolated Analog Output Module

Honeywell 51155506-100 Isolated Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 51155506-100

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51155506-100, also cataloged as the 51155506-100 Isolated Analog Output Module, operates as a dedicated hardware component for multi-channel analog signal execution within Honeywell C200 controller chassis platforms. It converts internal digital control commands into 6 electrically isolated analog output signals, driving field control elements such as control valves, variable frequency drives, and positioners.

Hardware Specifications

Parameter Specification
Model 51155506-100
Brand Honeywell
Origin USA
Weight 0.24 kg
Dimensions 3.5 cm x 14 cm x 14.5 cm
Operating Temp 0 to 60 deg C
Power Consumption 5.5 W (Backplane Bus Load)
Output Channels 6 channels
Signal Output Types Configurable (Voltage or Current)
Channel Isolation Electrical galvanic isolation
System Compatibility Honeywell C200 Controller Family

4-20 mA HART Loop Protocol & Galvanic Channel Isolation

The 51155506-100 incorporates dedicated digital-to-analog converters paired with individual galvanic isolation barriers on each of its 6 channels. This design isolates channel ground potentials from the main C200 backplane logic, preventing ground loop formation and high-frequency noise injection. When interface lines drive field actuators operating over the 4-20 mA HART loop protocol, the low-impedance channel drivers maintain high signal fidelity and step-response timing without affecting adjacent output circuits.

Frequently Asked Questions

Q: Can channels on the 51155506-100 be independently configured for different output signal ranges?

A: Yes, each of the 6 isolated output channels can be software-configured individually for either voltage or current loop output modes via the controller configuration environment.

Q: Does inserting the 51155506-100 module require shutting down the C200 chassis power?

A: To prevent backplane communication errors and output transients, field power supplies and chassis rack power must be switched off prior to physical insertion or extraction of the module.

Field Installation Guidelines

  1. Power down the C200 controller chassis and field power loops before seating the module into the designated slot.
  2. Align the module circuit board with the chassis card guides and push firmly until the rear connector fully engages the backplane header.
  3. Tighten top and bottom retaining screws to secure the module faceplate against the rack frame and establish chassis ground continuity.
  4. Route field output wiring using shielded twisted-pair cables, grounding the cable shields at a single chassis ground point to prevent ground loops across the 4-20 mA loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more