Configured for precision resistance temperature detection in MasterLogic-200 PLC networks, the Honeywell 2MLF-RD4A (2MLF-RD4A Resistance Temperature Detector Input Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 2MLF-RD4A
Brand Honeywell
Origin South Korea
Weight 0.15 kg
Dimensions Standard MasterLogic I/O Module Form Factor
Operating Temp 0 to 55 deg C
Power Consumption 450 mA at 5 VDC (backplane bus load)
Input Channels 4 channels
Conversion Speed 40 ms / channel
Accuracy +/-0.2% or less (at 25 deg C), +/-0.3% or less (at 0 to 55 deg C)
Wiring Method 3-wire system
Terminal Connection 18-point terminal block

Process Control & Resistance Signal Conditioning

The 2MLF-RD4A module executes analog-to-digital signal conversion across four dedicated RTD input channels. Internal channel-to-channel isolation hardware suppresses common-mode noise and ground loop currents across field-side sensor lines. To maintain high process accuracy, the module incorporates dynamic excitation current loops and cold junction compensation (CJC) reference algorithms for thermal signal stability across the 0 to 55 deg C ambient operating range.

Frequently Asked Questions

Q: What sensor wiring configuration is supported by the 2MLF-RD4A terminal block?

A: The module directly supports 3-wire RTD sensor configurations connected to the removable 18-point terminal block to compensate for lead-wire resistance.

Q: What is the backplane power draw for this RTD module?

A: The 2MLF-RD4A draws a nominal 450 mA current from the internal 5 VDC backplane power bus.

Field Installation Guidelines

  1. Power down the PLC base rack prior to installing or removing the 2MLF-RD4A module to prevent electrical damage to backplane contacts.
  2. Align the module with the base rack guide slots and press firmly until the top and bottom retaining latches lock into position.
  3. Wire the RTD field elements using shielded 3-wire cables, terminating the shield braid at a single earth ground bar within the control enclosure.
  4. Ensure signal wiring is physically separated from high-voltage AC power lines and drive cables to prevent inductive coupling and analog measurement jitter.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more