Skip to content

What are you looking for?


You may also like

General Electric DS200SLCCG1ACC LAN Communication ModuleGeneral Electric DS200SLCCG1ACC LAN Communication ModuleGeneral Electric DS200SLCCG1ACC LAN Communication Module
General Electric DS200SLCCG1ACC LAN Communication Module
General Electric DS200SLCCG1ACC LAN Communication Module
General Electric DS200SLCCG1ACC LAN Communication Module

General Electric DS200SLCCG1ACC LAN Communication Module


Only 10 left - Selling fast

PRODUCT SKU : DS200SLCCG1ACC

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for network interfacing within Mark V drive and turbine control platforms, the GE DS200SLCCG1ACC (DS200SLCCG1 LAN Communication Card) provides direct physical data exchange and local control processing.

Hardware Specifications

Parameter Specification
Model DS200SLCCG1ACC
Brand General Electric
Core Function LAN communication and processor interfacing

Industrial Control & Firmware Compatibility

The DS200SLCCG1ACC integrates a LAN Control Processor (LCP) and utilizes dual-ported RAM to facilitate deterministic data exchange with the host drive control board. For consistent system operation, the backplane bus communication velocity must remain synchronized with the LCP processing cycle to prevent data bottlenecks. Firmware-related parameters are managed via the two onboard EPROM memory modules; these components must maintain version parity with the host controller firmware to ensure correct I/O density scaling and operational stability. The module supports both isolated and non-isolated communication channels, requiring strict adherence to hardware configuration standards to prevent electrical noise coupling from the network medium into the control bus.

Frequently Asked Questions

Q: How is the module interfaced with the host drive controller?

A: The board utilizes dual-ported RAM to create a shared memory buffer between the LCP and the drive control board. This allows for simultaneous, independent access by both microprocessors for high-speed data transfer without external polling.

Q: What is the utility of the attachable alphanumeric keypad?

A: The 16-position alphanumeric display provides a physical interface for users to access system control settings and perform local diagnostics directly on the communication module, facilitating rapid status assessment.

Field Installation Guidelines

  • Physical Seating: Ensure the card is inserted into the designated drive cabinet slot. Verify that all backplane connectors are fully engaged to prevent intermittent communication failures, which can trigger system-wide control faults.
  • Shielding and Grounding: The module incorporates both isolated and non-isolated circuitry. Ensure that external network cabling is properly shielded and that the cabinet ground is securely bonded. Failure to isolate the signal path correctly can result in ground loops affecting data integrity.
  • Memory Handling: When replacing or servicing the EPROM memory modules, utilize ESD-safe handling procedures. Ensure proper orientation during installation to prevent damage to the U1 LCP and its peripheral support logic.
  • Diagnostic Verification: Following installation, attach the 16-position keypad to the designated port to verify initialization. Monitor for error codes or status messages that indicate successful handshaking between the card and the host drive controller.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more