Overview  

The GE UR6AV module is a digital input expansion unit designed for the Multilin Universal Relay (UR) series. It provides eight dedicated input channels, enabling reliable signal acquisition and monitoring for power system protection and automation applications.

Technical Specifications

  • Manufacturer: General Electric Multilin

  • Model: UR6AV

  • Type: Digital Input Module

  • Input Channels: 8 digital inputs

  • Input Type: Dry contact digital input

  • Nominal Voltage: 24 V DC (standard operating voltage)

  • Compatibility: Fully integrates with GE Multilin UR series relays

  • Weight: Approx. 0.8 kg

  • Dimensions: 170 mm × 105 mm × 32 mm

  • Operating Temperature: -20°C to +70°C (-4°F to +158°F)

  • Storage Temperature: -40°C to +70°C (-40°F to +158°F)

  • Humidity Range: 5% to 95% RH (non-condensing)

Key Features

  • Eight independent digital input channels for flexible monitoring

  • Seamless integration with UR series relays for expanded functionality

  • High reliability in industrial and utility environments

  • Compact design for efficient installation and maintenance

Applications

  • Power system event monitoring

  • Relay input expansion for automation systems

  • Signal acquisition in substations and industrial facilities

  • Integration into UR relay-based protection schemes

FAQ

  • Q: How many input channels does the UR6AV provide?  A: The module offers 8 digital input channels.

  • Q: What type of inputs are supported?  A: Dry contact digital inputs with nominal 24 V DC operation.

  • Q: Is the UR6AV compatible with all UR series relays?  A: Yes, it is designed specifically for the Multilin UR series.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more