Skip to content

What are you looking for?


You may also like

GE Multilin SR750 | 750-P5-G5-S5-HI-A20-G | Feeder Management RelayGE Multilin SR750 | 750-P5-G5-S5-HI-A20-G | Feeder Management RelayGE Multilin SR750 | 750-P5-G5-S5-HI-A20-G | Feeder Management Relay
GE Multilin SR750 | 750-P5-G5-S5-HI-A20-G | Feeder Management Relay
GE Multilin SR750 | 750-P5-G5-S5-HI-A20-G | Feeder Management Relay
GE Multilin SR750 | 750-P5-G5-S5-HI-A20-G | Feeder Management Relay

GE Multilin SR750 | 750-P5-G5-S5-HI-A20-G | Feeder Management Relay


Only 10 left - Selling fast

PRODUCT SKU : 750-P5-G5-S5-HI-A20-G

PRODUCT TYPE : Feeder Management Relay

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Multilin SR750 Feeder Management Relay is part of the SR750 Series, designed to provide advanced protection, monitoring, and control for electrical feeders. The SR750-P5-G5-S5-HI-A20-G integrates multiple current input options, analog outputs, and breaker control functions, making it a versatile solution for industrial and utility power systems.

Although discontinued by the manufacturer, this relay remains a critical spare part for legacy installations requiring reliable feeder protection.

Technical Specifications

  • Manufacturer: GE Multilin

  • Model Number: SR750-P5-G5-S5-HI-A20-G

  • Product Type: Feeder Management Relay

  • Phase Current Inputs: 5 A CT secondaries

  • Zero Sequence Current Inputs: 5 A

  • Sensitive Ground Current Input: 5 A

  • Control Power: 88–300 VDC, 70–265 VAC (48–62 Hz)

  • Analog Outputs: Eight 4–20 mA channels

  • Breaker Control: Integrated breaker close functionality

  • Weight: 11 lbs (approx. 5 kg)

Key Features

  • Comprehensive feeder protection with multiple current input options

  • Eight analog outputs for monitoring and control integration

  • Breaker control and monitoring functions included

  • Designed for industrial and utility feeder applications

Application Scenarios

  • Electrical feeder protection in industrial facilities

  • Utility distribution systems requiring advanced relay functions

  • Legacy system maintenance and spare part replacement

FAQ

Q: What is the main function of the SR750 relay?  

A: It provides feeder protection, monitoring, and breaker control.

Q: How many analog outputs are available?  

A: The relay includes eight 4–20 mA analog outputs.

Q: Is the SR750 still in production?  

A: No, it has been discontinued, but remains available as a spare part.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more