PRODUCT SKU : IS210AEAAH1BGB

PRODUCT TYPE : Communication Interface Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS210AEAAH1BGB, also cataloged as the IS210AEAA Communication Interface Board, operates as a dedicated hardware component for multi-channel data processing and system networking within Mark VI platforms.

Hardware Specifications

Parameter Specification
Model IS210AEAAH1BGB
Brand GE
Origin USA
Weight 1.2 kg
Dimensions 350 x 250 x 60 mm
Operating Temp -40 to 70 deg C
Power Consumption 24 VDC nominal input
Output Voltage Range 0 to 10 VDC maximum
Enclosure Protection Rated NEMA 4 / IP65
Vibration Limit 5 g up to 2 kHz
Power Monitoring Analog/digital status feedback via J301 backplane connector

Backplane Bus Communication and Firmware Flash Compatibility

The IS210AEAAH1BGB operates on a VME architecture to interface main controllers with I/O cards and the IONet control network layer. The hardware routes parallel data streams between field circuitry and FPGA processing logic across multiple input and output channels. Power status signals route through the J301 backplane connector to enable continuous internal bus monitoring. Deterministic bus timings maintain operational synchronization across backplane slots, while underlying firmware flash compatibility supports reliable hardware handshaking during full-speed network transactions.

Frequently Asked Questions

Q: How does the board receive power status feedback from the system?

A: Analog and digital power supply monitoring signals are routed directly into the module through the J301 backplane connector interface.

Q: What network protocols or bus architectures does this module interface with?

A: The board interfaces via a VME backplane architecture, facilitating primary data transfer between main controllers, distributed I/O boards, and the IONet system network.

Q: Is hot-swapping supported for the IS210AEAAH1BGB during active rack operation?

A: Hot-swapping must follow strict Mark VI system procedures; power off the slot or ensure the VME bus section is isolated prior to module extraction to prevent backplane bus disruptions.

Field Installation Guidelines

Verify that all power supplies connected to the rack chassis are de-energized before inserting or removing the module. Align the board edges with the enclosure card guides and press firmly until the J301 backplane connector seats completely into the bus motherboard. Tighten faceplate securing screws to maintain chassis ground continuity and prevent mechanical dislodgement from high vibrations up to 5 g. Ensure field wiring cables maintain proper strain relief and are routed clear of high-voltage lines to minimize electromagnetic interference. Wear a grounded ESD wrist strap throughout the installation process to prevent static damage to sensitive FPGA components.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more