Skip to content

What are you looking for?


You may also like

GE IS200TBAIS1C Mark VIe Analog Input/Output Terminal BoardGE IS200TBAIS1C Mark VIe Analog Input/Output Terminal Board
GE IS200TBAIS1C Mark VIe Analog Input/Output Terminal Board
GE IS200TBAIS1C Mark VIe Analog Input/Output Terminal Board

GE IS200TBAIS1C Mark VIe Analog Input/Output Terminal Board


Only 10 left - Selling fast

PRODUCT SKU : IS200TBAIS1C

PRODUCT TYPE : Analog Input/Output Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for analog signal processing in Mark VIe safety-integrated systems, the GE IS200TBAIS1C (IS200TBAIS1C Analog Input/Output Terminal Board) provides direct physical/electrical execution. This terminal board supports both simplex and triple modular redundancy (TMR) configurations, managing thermocouple, current loop, and voltage signals while facilitating precise current regulation through integrated shunt measurement circuitry.

Hardware Specifications

Parameter Specification
Model IS200TBAIS1C
Brand General Electric
Origin USA
Weight Not specified
Dimensions Standard Mark VIe terminal board form factor
Operating Temp Industrial standard range
Power Consumption Dependent on connected I/O loops
Connection Type 3 x DC-37 pin I/O processor connectors

Triple Modular Redundancy (TMR) and Fail-Safe Execution

The IS200TBAIS1C is engineered for safety-certified applications within the Mark VIeS SIS environment. In TMR 2oo3 configurations, the terminal board enables signal fanning, where inputs are distributed across the R, S, and T control channels. The board utilizes an integrated measuring shunt to aggregate current from triple-connected output drivers, providing a composite signal to the I/O processors for accurate setpoint regulation. The design enforces fail-safe state execution, ensuring that in the event of an I/O processor discrepancy, the voter logic maintains the safety-critical state. Note that the 200 mA output option is restricted in YAIC-based SIS applications to ensure compliance with certified safety parameters.

Frequently Asked Questions

Q: Is the IS200TBAIS1C compatible with simplex application topologies?

A: Yes. The board utilizes a dedicated single connector (R1) for simplex applications, while all three DC-37 pin connectors are utilized for TMR configurations to support redundant processing.

Q: How is output current handled in TMR mode?

A: In TMR mode, the terminal board aggregates the currents from the three connected output drivers. An onboard measuring shunt calculates the total current, which is then fed back to the I/O processors to ensure precise regulation to the commanded setpoint.

Field Installation Guidelines

  • Interface Cabling: Connect I/O processors to the three DC-37 pin ports. For simplex setups, ensure the R1 port is utilized. For TMR, ensure cabling from all three processors (R, S, T) is verified against the system wiring schematic to prevent signal phase or addressing errors.
  • Shielding and Grounding: To maintain safety certification integrity, land all cable shields on the designated terminal board grounding points. Minimize path impedance to the system common earth ground to avoid noise-induced errors in analog measurement circuits.
  • Terminal Block Torque: Apply proper torque to the barrier-style terminal blocks when landing field wiring. Loose connections can introduce resistive fluctuations, causing instability in current-loop feedback signals.
  • Environmental Considerations: Ensure the installation environment remains within rated limits. Avoid proximity to high-frequency power switching equipment to prevent EMI coupling into sensitive low-level analog inputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Programmable Logic Controllers (PLCs) form the backbone of modern industrial automation systems. They interface directly with field devices such as solenoid valves, indicator lights, motor starters, and interposing relays. Selecting the correct digital output module ensures high system availability and long hardware service life.

Read more
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more