Configured for discrete signal acquisition in Mark VIe distributed control platforms, the GE IS200STCIH6A (IS200STCIH6A Contact Input Terminal Board) provides direct physical/electrical execution of field contact monitoring.

Hardware Specifications

Parameter Specification
Model IS200STCIH6A
Brand General Electric
Origin USA
Input Capacity 24 contact inputs
Input Voltage Range 24 V DC, 48 V DC, 125 V DC

Industrial Control and I/O Density Scaling

The IS200STCIH6A functions as a termination interface for field-level discrete inputs, supporting nominal voltages of 24, 48, and 125 V DC. The board incorporates integrated noise suppression circuitry to protect against transient surges and high-frequency noise inherent in industrial environments. System integration is achieved through Mark VIe or Mark VIeS controller compatibility, utilizing the terminal board's ability to map 24 independent inputs to the associated I/O pack. Firmware flash compatibility across the Mark VIe ecosystem ensures that input timing and status reporting are synchronized with controller scan rates, facilitating efficient I/O density scaling during system expansion or migration.

Frequently Asked Questions

Q: Does the IS200STCIH6A support signal loop power generation?

A: No. The STCI board serves as an interface for external field contacts. Stimulation voltage must be provided by external sources; the board provides the termination and filtering required to condition these signals for the I/O pack.

Q: Can the STCI board be mounted in different orientations?

A: Yes. The board is designed for flexibility, supporting both standard DIN-rail mounting and direct flat-surface installation within the control cabinet, depending on specific panel layout requirements.

Field Installation Guidelines

  1. Mounting: Secure the board onto a standard DIN-rail or directly to the cabinet backplane using the mounting holes provided. Ensure the chassis ground point is firmly connected to the panel ground bus to ensure effective noise suppression.
  2. Wiring Termination: Connect field contact wiring to the designated screw terminals. For 125 V DC inputs, maintain appropriate wire insulation ratings and physical separation from low-voltage signal cabling to prevent cross-coupling.
  3. Shielding: Terminate cable shields at the cabinet ground point rather than the terminal board itself, unless specific site grounding diagrams dictate otherwise. Use ferrules on stranded conductors to ensure reliable mechanical connection within the terminal blocks.
  4. Verification: After installation, perform a continuity check on all field loops. Use a digital multimeter to confirm that the stimulation voltage is correctly present at the terminal entry point before signaling the I/O pack.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more