Skip to content

What are you looking for?


You may also like

GE IS200ESYSH3A I/O Terminal BoardGE IS200ESYSH3A I/O Terminal BoardGE IS200ESYSH3A I/O Terminal Board
GE IS200ESYSH3A I/O Terminal Board
GE IS200ESYSH3A I/O Terminal Board
GE IS200ESYSH3A I/O Terminal Board

GE IS200ESYSH3A I/O Terminal Board


Only 10 left - Selling fast

PRODUCT SKU : IS200ESYSH3A

PRODUCT TYPE : Terminal Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS200ESYSH3A, also cataloged as the IS200ESYSH3A I/O Terminal Board, operates as a dedicated hardware component for excitation control system interface within EX2100e platforms.

Hardware Specifications

Parameter Specification
Model IS200ESYSH3A
Brand General Electric
Origin USA
Control Section M1
Redundancy Type Simplex Control

Profinet / EtherNet/IP Deterministic Networks

The IS200ESYSH3A acts as the primary signal acquisition node for the EX2100e system, facilitating the exchange of field I/O data through an attached HSLA high-speed serial link (HSSL) daughterboard. This architecture ensures deterministic communication between the ESYS terminal board and the central control system. The board supports the integration of two generator current transformer (CT) inputs (1 A / 5 A) and two three-phase potential transformer (PT) voltage inputs for real-time feedback processing. I/O density scaling is achieved through the board's onboard logic, which conditions these analog inputs and provides two discrete trip relay outputs configured for 2-of-3 hardware voting logic. Firmware flash compatibility is maintained across the ESYS group, ensuring consistent interface behavior regardless of specific H-group redundancy mode.

Frequently Asked Questions

Q: Is the IS200ESYSH3A compatible with redundant (TMR) configurations?

A: No. The IS200ESYSH3A is specifically designated as an H3 group model, which restricts its operation to simplex control mode. Redundant configurations require different H-series variations.

Q: Can the board handle both 1 A and 5 A CT inputs simultaneously?

A: The board supports generator CT inputs rated at 1 A or 5 A. The specific configuration must be matched to the external CT secondary rating to ensure accurate current feedback for the excitation regulator.

Field Installation Guidelines

  1. Mounting: Ensure the board is mounted in a stable, vibration-free environment within the EX2100e cabinet. Secure all mounting hardware to guarantee a solid ground reference between the terminal board chassis and the control enclosure.
  2. Signal Segregation: Route low-level PT and CT feedback signals away from high-power PWM motor cables or inductive load switching lines. Utilize shielded cabling for all analog inputs to mitigate electromagnetic interference.
  3. Connector Seating: Verify the integrity of the HSLA HSSL daughterboard connection. Ensure that all ribbon cables and D-sub connectors are fully seated and locked to maintain high-speed communication continuity.
  4. Relay Termination: The trip relay outputs are intended for high-reliability lockout devices. Ensure that external circuit wiring is properly sized and that suppression diodes are utilized if driving inductive loads to protect the onboard relay contacts.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more